Examinando por Materia "pH"
Mostrando 1 - 9 de 9
Resultados por página
Opciones de ordenación
Ítem The Box-Benkhen experimental design for the optimization of the electrocatalytic treatment of wastewaters with high concentrations of phenol and organic matter.(IWA PUBLISHING, 2009-01-01) GilPavas, Edison; Betancourt, Alejandra; Angulo, Monica; Dobrosz-Gomez, Izabela; Angel Gomez-Garcia, Miguel; GilPavas, Edison; Betancourt, Alejandra; Angulo, Monica; Dobrosz-Gomez, Izabela; Angel Gomez-Garcia, Miguel; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)In this work, the Box-Benkhen experimental Design (BBD) was applied for the optimization of the parameters of the electrocatalytic degradation of wastewaters resulting from a phenolic resins industry placed in the suburbs of Medellin (Colombia). The direct and the oxidant assisted electro-oxidation experiments were carried out in a laboratory scale batch cell reactor, with monopolar configuration, and electrodes made of graphite (anode) and titanium (cathode). A multifactorial experimental design was proposed, including the following experimental variables: initial phenol concentration, conductivity, and pH. The direct electro-oxidation process allowed to reach ca. 88% of phenol degradation, 38% of mineralization (TOC), 52% of Chemical Oxygen Demand (COD) degradation, and an increase in water biodegradability of 13%. The synergetic effect of the electro-oxidation process and the respective oxidant agent (Fenton reactant, potassium permanganate, or sodium persulfate) let to a significant increase in the rate of the degradation process. At the optimized variables values, it was possible to reach ca. 99% of phenol degradation, 80% of TOC and 88% of COD degradation. A kinetic study was accomplished, which included the identification of the intermediate compounds generated during the oxidation process.Ítem Coagulation-flocculation sequential with Fenton or Photo-Fenton processes as an alternative for the industrial textile wastewater treatment(Editorial Board, 2017-04-15) GilPavas, E.; Dobrosz-Gómez, I.; Gómez-García, M.Á.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Desarrollo y Diseño de ProcesosIn this study, the industrial textile wastewater was treated using a chemical-based technique (coagulation-flocculation, C-F) sequential with an advanced oxidation process (AOP: Fenton or Photo-Fenton). During the C-F, Al2(SO4)3 was used as coagulant and its optimal dose was determined using the jar test. The following operational conditions of C-F, maximizing the organic matter removal, were determined: 700 mg/L of Al2(SO4)3 at pH = 9.96. Thus, the C-F allowed to remove 98% of turbidity, 48% of Chemical Oxygen Demand (COD), and let to increase in the BOD5/COD ratio from 0.137 to 0.212. Subsequently, the C-F effluent was treated using each of AOPs. Their performances were optimized by the Response Surface Methodology (RSM) coupled with a Box-Behnken experimental design (BBD). The following optimal conditions of both Fenton (Fe2+/H2O2) and Photo-Fenton (Fe2+/H2O2/UV) processes were found: Fe2+ concentration = 1 mM, H2O2 dose = 2 mL/L (19.6 mM), and pH = 3. The combination of C-F pre-treatment with the Fenton reagent, at optimized conditions, let to remove 74% of COD during 90 min of the process. The C-F sequential with Photo-Fenton process let to reach 87% of COD removal, in the same time. Moreover, the BOD5/COD ratio increased from 0.212 to 0.68 and from 0.212 to 0.74 using Fenton and Photo-Fenton processes, respectively. Thus, the enhancement of biodegradability with the physico-chemical treatment was proved. The depletion of H2O2 was monitored during kinetic study. Strategies for improving the reaction efficiency, based on the H2O2 evolution, were also tested. © 2017 Elsevier LtdÍtem Coagulation-flocculation sequential with Fenton or Photo-Fenton processes as an alternative for the industrial textile wastewater treatment(Editorial Board, 2017-04-15) GilPavas, E.; Dobrosz-Gómez, I.; Gómez-García, M.Á.; GilPavas, E.; Dobrosz-Gómez, I.; Gómez-García, M.Á.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)In this study, the industrial textile wastewater was treated using a chemical-based technique (coagulation-flocculation, C-F) sequential with an advanced oxidation process (AOP: Fenton or Photo-Fenton). During the C-F, Al2(SO4)3 was used as coagulant and its optimal dose was determined using the jar test. The following operational conditions of C-F, maximizing the organic matter removal, were determined: 700 mg/L of Al2(SO4)3 at pH = 9.96. Thus, the C-F allowed to remove 98% of turbidity, 48% of Chemical Oxygen Demand (COD), and let to increase in the BOD5/COD ratio from 0.137 to 0.212. Subsequently, the C-F effluent was treated using each of AOPs. Their performances were optimized by the Response Surface Methodology (RSM) coupled with a Box-Behnken experimental design (BBD). The following optimal conditions of both Fenton (Fe2+/H2O2) and Photo-Fenton (Fe2+/H2O2/UV) processes were found: Fe2+ concentration = 1 mM, H2O2 dose = 2 mL/L (19.6 mM), and pH = 3. The combination of C-F pre-treatment with the Fenton reagent, at optimized conditions, let to remove 74% of COD during 90 min of the process. The C-F sequential with Photo-Fenton process let to reach 87% of COD removal, in the same time. Moreover, the BOD5/COD ratio increased from 0.212 to 0.68 and from 0.212 to 0.74 using Fenton and Photo-Fenton processes, respectively. Thus, the enhancement of biodegradability with the physico-chemical treatment was proved. The depletion of H2O2 was monitored during kinetic study. Strategies for improving the reaction efficiency, based on the H2O2 evolution, were also tested. © 2017 Elsevier LtdÍtem Mejoramiento de medio de cultivo para la producción de biomasa y polisacáridos a partir de Amauroderma omphalodes(Universidad EAFIT, 2022) Almánzar Agudelo, María Mercedes; Moreno Valencia, Kevin; Marín Palacio, Luz DeisyÍtem Optimization and toxicity assessment of a combined electrocoagulation, H2O2/Fe2+/UV and activated carbon adsorption for textile wastewater treatment(Elsevier, 2019-02-15) GilPavas, E; Dobrosz-Gomez, I; Gomez-Garcia, MA; GilPavas, E; Dobrosz-Gomez, I; Gomez-Garcia, MA; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)In this study, the potential application of sequential Electrocoagulation + Fenton (F) or Photo-Fenton (PF) + Active carbon adsorption (EC + F/PF + AC) processes were analyzed as alternatives for the treatment of an industrial textile wastewater resulting from an industrial facility located in Medellín (Colombia). In order to maximize the organic matter degradation, each step of the treatment was optimized using the Response Surface Methodology. At first, the optimal performance of EC was achieved with Fe electrodes operating at pH = 7, jEC = 10 mA/cm2 and 60 rpm, during 10 min of electrolysis. At these conditions, EC let to remove 94% of the dye's color, 56% of the COD and 54% of the TOC. Next, sequentially applied Fenton or photo-Fenton process (i.e., EC + F/PF), operating at the optimized conditions (pH = 4.3, [Fe2+] = 1.1 mM, [H2O2] = 9.7 mM, stirring velocity = 100 rpm and reaction time = 60 min.), improved the quality of the treated effluent. The EC + F let to achieve total color reduction, as well as COD and TOC removals of 72 and 75%, respectively. The EC + PF reached 100% of color, 76% of COD and 78% of TOC reductions. The EC + F/PF processes were more efficient than EC in elimination of low molecular weight (<5 kDa) compounds from wastewater. Moreover, the BOD5/COD ratio increased from 0.21 to 0.42 and from 0.21 to 0.46 using EC + F and EC + PF processes, respectively. However, EC + F/PF were not fully effective for the removal of acute toxicity to Artemia salina: 20% and 60% of reduction in toxicity using EC + F and EC + PF, respectively, comparing to very toxic (100%) raw textile wastewater. Thus, activated carbon adsorption was applied as an additional step to complete the treatment. After AC adsorption, the acute toxicity decreased to 10% and 0% using EC + F and EC + PF, respectively. The total operational costs, including chemical reagents, electrodes, energy consumption and sludge disposal, were of 1.65 USD/m3 and 2.3 USD/m3 for EC + F and EC + PF, respectively. © 2018 Elsevier B.V.Ítem Optimization and toxicity assessment of a combined electrocoagulation, H2O2/Fe2+/UV and activated carbon adsorption for textile wastewater treatment(Elsevier, 2019-02-15) GilPavas, E; Dobrosz-Gomez, I; Gomez-Garcia, MA; Universidad EAFIT. Departamento de Ingeniería de Procesos; Desarrollo y Diseño de ProcesosIn this study, the potential application of sequential Electrocoagulation + Fenton (F) or Photo-Fenton (PF) + Active carbon adsorption (EC + F/PF + AC) processes were analyzed as alternatives for the treatment of an industrial textile wastewater resulting from an industrial facility located in Medellín (Colombia). In order to maximize the organic matter degradation, each step of the treatment was optimized using the Response Surface Methodology. At first, the optimal performance of EC was achieved with Fe electrodes operating at pH = 7, jEC = 10 mA/cm2 and 60 rpm, during 10 min of electrolysis. At these conditions, EC let to remove 94% of the dye's color, 56% of the COD and 54% of the TOC. Next, sequentially applied Fenton or photo-Fenton process (i.e., EC + F/PF), operating at the optimized conditions (pH = 4.3, [Fe2+] = 1.1 mM, [H2O2] = 9.7 mM, stirring velocity = 100 rpm and reaction time = 60 min.), improved the quality of the treated effluent. The EC + F let to achieve total color reduction, as well as COD and TOC removals of 72 and 75%, respectively. The EC + PF reached 100% of color, 76% of COD and 78% of TOC reductions. The EC + F/PF processes were more efficient than EC in elimination of low molecular weight (<5 kDa) compounds from wastewater. Moreover, the BOD5/COD ratio increased from 0.21 to 0.42 and from 0.21 to 0.46 using EC + F and EC + PF processes, respectively. However, EC + F/PF were not fully effective for the removal of acute toxicity to Artemia salina: 20% and 60% of reduction in toxicity using EC + F and EC + PF, respectively, comparing to very toxic (100%) raw textile wastewater. Thus, activated carbon adsorption was applied as an additional step to complete the treatment. After AC adsorption, the acute toxicity decreased to 10% and 0% using EC + F and EC + PF, respectively. The total operational costs, including chemical reagents, electrodes, energy consumption and sludge disposal, were of 1.65 USD/m3 and 2.3 USD/m3 for EC + F and EC + PF, respectively. © 2018 Elsevier B.V.Ítem The removal of the trivalent chromium from the leather tannery wastewater: the optimisation of the electro-coagulation process parameters.(IWA PUBLISHING, 2011-02-01) GilPavas, E.; Dobrosz-Gomez, I.; Gomez-Garcia, M. A.; GilPavas, E.; Dobrosz-Gomez, I.; Gomez-Garcia, M. A.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)The capacity of the electro-coagulation (EC) process for the treatment of the wastewater containing Cr3+, resulting from a leather tannery industry placed in Medellin (Colombia), was evaluated. In order to assess the effect of some parameters, such as: the electrode type (Al and/or Fe), the distance between electrodes, the current density, the stirring velocity, and the initial Cr3+ concentration on its efficiency of removal (%RCr+3), a multifactorial experimental design was used. The %RCr3+ was defined as the response variable for the statistical analysis. In order to optimise the operational values for the chosen parameters, the response surface method (RSM) was applied. Additionally, the Biological Oxygen Demand (BOD5), the Chemical Oxygen Demand (COD), and the Total Organic Carbon (TOC) were monitored during the EC process. The electrodes made of aluminium appeared to be the most effective in the chromium removal from the wastewater under study. At pH equal to 4.52 and at 28 degrees C, the optimal conditions of Cr3+ removal using the EC process were found, as follows: the initial Cr3+ concentration=3,596 mg/L, the electrode gap=0.5 cm, the stirring velocity=382.3 rpm, and the current density=57.87 mA/cm2. At those conditions, it was possible to reach 99.76% of Cr3+ removal, and 64% and 61% of mineralisation (TOC) and COD removal, respectively. A kinetic analysis was performed in order to verify the response capacity of the EC process at optimised parameter values.Ítem Sensibilidad Paramétrica y Condiciones Seguras de Operación de la Hidrólisis del Anhídrido Acético en un Reactor Batch(Centro de Informacion Tecnologica, 2016-01-01) Gaviria, G.H.; GilPavas, E.; Dobrosz-Gómez, I.; Gómez, M.Á.; Gaviria, G.H.; GilPavas, E.; Dobrosz-Gómez, I.; Gómez, M.Á.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)The results of a study on the parametric sensitivity of acetic acid production by hydrolysis of acetic anhydride, using acid homogeneous catalysis in a batch reactor, are presented. Dimensionless parameters of mass and energy balances were fitted using experimental data available in the literature that includes the variation of the reaction temperature for different sulfuric acid concentrations (3% to 5%). Then, from the analysis of the intrinsic mathematical properties of the concentration-temperature phase plane, the critical operating conditions were defined. Thus, it was possible to determine the specific values of the safe operating conditions for the catalyzed hydrolysis of acetic anhydride, in the function of catalyst concentration.Ítem Treatment of automotive industry oily wastewater by electrocoagulation: statistical optimization of the operational parameters.(IWA PUBLISHING, 2009-11-01) GilPavas, Edison; Molina-Tirado, Kevin; Angel Gomez-Garcia, Miguel; GilPavas, Edison; Molina-Tirado, Kevin; Angel Gomez-Garcia, Miguel; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)An electrocoagulation process was used for the treatment of oily wastewater generated from an automotive industry in Medellin (Colombia). An electrochemical cell consisting of four parallel electrodes (Fe and Al) in bipolar configuration was implemented. A multifactorial experimental design was used for evaluating the influence of several parameters including: type and arrangement of electrodes, pH, and current density. Oil and grease removal was defined as the response variable for the statistical analysis. Additionally, the BOD(5), COD, and TOC were monitored during the treatment process. According to the results, at the optimum parameter values (current density = 4.3 mA/cm(2), distance between electrodes = 1.5 cm, Fe as anode, and pH = 12) it was possible to reach a c.a. 95% oils removal, COD and mineralization of 87.4% and 70.6%, respectively. A final biodegradability (BOD(5)/COD) of 0.54 was reached.