Logotipo del repositorio
  • English
  • Español
  • Français
  • Português
  • Iniciar sesión
    ¿Has olvidado tu contraseña?
Logotipo del repositorio
  • Comunidades
  • Listar por
  • English
  • Español
  • Français
  • Português
  • Iniciar sesión
    ¿Has olvidado tu contraseña?
  1. Inicio
  2. Examinar por materia

Examinando por Materia "Biomechanics"

Mostrando 1 - 20 de 21
Resultados por página
Opciones de ordenación
  • No hay miniatura disponible
    Ítem
    Aplicaciones de la biónica en proyectos de diseño mecánico
    (Universidad EAFIT, 2010) Ferrer Gómez, Carolina; Otálvaro Guzmán, Viviana; o
  • No hay miniatura disponible
    Ítem
    Biomechanical characteristics of regenerated cortical bone in the canine mandible
    (WILEY-BLACKWELL, 2011-07-01) Zapata, Uriel; Opperman, Lynne A.; Kontogiorgos, Elias; Elsalanty, Mohammed E.; Dechow, Paul C.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)
    To test the mechanical properties of regenerate cortical bone created using mandibular bone transport (MBT) distraction, five adult male American foxhound dogs underwent unilateral distraction of the mandible with a novel MBT device placed to linearly repair a 30-35 mm bone defect. The animals were sacrificed 12 weeks after the beginning of the consolidation period. Fourteen cylindrical specimens were taken from the inner (lingual) and outer (buccal) plates of the reconstructed mandible and 21 control specimens were removed from the contralateral aspect of the mandible. The mechanical properties of the 35 cylindrical cortical bone specimens were assessed by using a non-destructive pulse ultrasound technique. Results showed that all of the cortical mechanical properties exhibit higher numerical values on the control side than the MBT regenerate side. In addition, both densities and the elastic moduli in the direction of maximum stiffness of the regenerate cortical bone specimens are higher on the lingual side than the buccal side. Interestingly, there is no statistical difference between elastic modulus (E1 and E2) in orthogonal directions throughout the 35 cortical specimens. The data suggest that not only is the regenerate canine cortical bone heterogeneous, but the elastic mechanical properties tend to approximate transverse isotropy at a tissue level, as opposed to control cortical bone, which is orthotropic. In addition, the elastic mechanical properties are higher not only on the control side but also in the lingual anatomical position, suggesting a stress shielding effect from the presence of the reconstruction plate. © 2011 John Wiley & Sons, Ltd.
  • No hay miniatura disponible
    Ítem
    Biomechanical configurations of mandibular transport distraction osteogenesis devices.
    (MARY ANN LIEBERT, INC, 2010-06-01) Zapata U; Elsalanty ME; Dechow PC; Opperman LA; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)
    Mandibular bone transport (MBT) distraction osteogenesis devices are used for achieving reconstruction of mandibular defects in a predictable way, with few complications, less complexity than other alternative surgical procedures, and minimal tissue morbidity. However, selection of appropriate MBT device characteristics is critical for ensuring both their mechanical soundness and their optimal distraction function for each patient's condition. This article assesses six characteristics of currently available MBT devices to characterize their design and function and to classify them in a way that assists the selection of the best device option for each clinical case. In addition, the present work provides a framework for both the biomechanical conception of new devices and the modification of existing ones.
  • No hay miniatura disponible
    Ítem
    Biomechanics of the canine mandible during bone transport distraction osteogenesis
    (ASME, 2014-11-01) Zapata, Uriel; Dechow, Paul C.; Watanabe, Ikuya; Elsalanty, Mohammed E.; Opperman, Lynne A.; Zapata, Uriel; Dechow, Paul C.; Watanabe, Ikuya; Elsalanty, Mohammed E.; Opperman, Lynne A.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de Ingeniería
    This study compared biomechanical patterns between finite element models (FEMs) and a fresh dog mandible tested under molar and incisal physiological loads in order to clarify the effect of the bone transport distraction osteogenesis (BTDO) surgical process. Three FEMs of dog mandibles were built in order to evaluate the effects of BTDO. The first model evaluated the mandibular response under two physiological loads resembling bite processes. In the second model, a 5.0 cm bone defect was bridged with a bone transport reconstruction plate (BTRP). In the third model, new regenerated bony tissue was incorporated within the defect to mimic the surgical process without the presence of the device. Complementarily, a mandible of a male American foxhound dog was mechanically tested in the laboratory both in the presence and absence of a BTRP, and mechanical responses were measured by attaching rosettes to the bone surface of the mandible to validate the FEM predictions. The relationship between real and predicted values indicates that the stress patterns calculated using FEM are a valid predictor of the biomechanics of the BTDO procedures. The present study provides an interesting correlation between the stiffness of the device and the biomechanical response of the mandible affected for bone transport. Copyright © 2014 by ASME.
  • No hay miniatura disponible
    Ítem
    Biomechanics of the canine mandible during bone transport distraction osteogenesis
    (ASME, 2014-11-01) Zapata, Uriel; Dechow, Paul C.; Watanabe, Ikuya; Elsalanty, Mohammed E.; Opperman, Lynne A.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)
    This study compared biomechanical patterns between finite element models (FEMs) and a fresh dog mandible tested under molar and incisal physiological loads in order to clarify the effect of the bone transport distraction osteogenesis (BTDO) surgical process. Three FEMs of dog mandibles were built in order to evaluate the effects of BTDO. The first model evaluated the mandibular response under two physiological loads resembling bite processes. In the second model, a 5.0 cm bone defect was bridged with a bone transport reconstruction plate (BTRP). In the third model, new regenerated bony tissue was incorporated within the defect to mimic the surgical process without the presence of the device. Complementarily, a mandible of a male American foxhound dog was mechanically tested in the laboratory both in the presence and absence of a BTRP, and mechanical responses were measured by attaching rosettes to the bone surface of the mandible to validate the FEM predictions. The relationship between real and predicted values indicates that the stress patterns calculated using FEM are a valid predictor of the biomechanics of the BTDO procedures. The present study provides an interesting correlation between the stiffness of the device and the biomechanical response of the mandible affected for bone transport. Copyright © 2014 by ASME.
  • No hay miniatura disponible
    Ítem
    Bone regeneration and docking site healing after bone transport distraction osteogenesis in the canine mandible
    (W.B. Saunders Ltd, 2012-01-01) Nagashima, L.K.; Rondon-Newby, M.; Zakhary, I.E.; Nagy, W.W.; Zapata, U.; Dechow, P.C.; Opperman, L.A.; Elsalanty, M.E.; Nagashima, L.K.; Rondon-Newby, M.; Zakhary, I.E.; Nagy, W.W.; Zapata, U.; Dechow, P.C.; Opperman, L.A.; Elsalanty, M.E.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de Ingeniería
    Purpose: Bone transport distraction osteogenesis provides a promising alternative to traditional grafting techniques. However, existing bone transport distraction osteogenesis devices have many limitations. The purpose of this research was to test a new device, the mandibular bone transport reconstruction plate, in an animal model with comparable mandible size to humans and to histologically and mechanically examine the regenerate bone. Materials and Methods: Eleven adult foxhounds were divided into an unreconstructed control group of 5 animals and an experimental group of 6 animals. In each animal, a 34-mm segmental defect was created in the mandible. The defect was reconstructed with a bone transport reconstruction plate. Histologic and biomechanical characteristics of the regenerate and unrepaired defect were analyzed and compared with bone on the contralateral side of the mandible after 4 weeks of consolidation. Results: The reconstructed defect was bridged with new bone, with little bone in the control defect. Regenerate density and microhardness were 22.3% and 42.6%, respectively, lower than the contralateral normal bone. Likewise, the anisotropy of the experimental group was statistically lower than in the contralateral bone. Half the experimental animals showed nonunion at the docking site. Conclusion: The device was very stable and easy to install and activate. After 1 month of consolidation, the defect was bridged with new bone, with evidence of active bone formation. Regenerate bone was less mature than the control bone. Studies are underway to identify when the regenerate properties compare with normal bone and to identify methods to augment bone union at the docking site. © 2012 American Association of Oral and Maxillofacial Surgeons.
  • No hay miniatura disponible
    Ítem
    Bone regeneration and docking site healing after bone transport distraction osteogenesis in the canine mandible
    (W.B. Saunders Ltd, 2012-01-01) Nagashima, L.K.; Rondon-Newby, M.; Zakhary, I.E.; Nagy, W.W.; Zapata, U.; Dechow, P.C.; Opperman, L.A.; Elsalanty, M.E.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)
    Purpose: Bone transport distraction osteogenesis provides a promising alternative to traditional grafting techniques. However, existing bone transport distraction osteogenesis devices have many limitations. The purpose of this research was to test a new device, the mandibular bone transport reconstruction plate, in an animal model with comparable mandible size to humans and to histologically and mechanically examine the regenerate bone. Materials and Methods: Eleven adult foxhounds were divided into an unreconstructed control group of 5 animals and an experimental group of 6 animals. In each animal, a 34-mm segmental defect was created in the mandible. The defect was reconstructed with a bone transport reconstruction plate. Histologic and biomechanical characteristics of the regenerate and unrepaired defect were analyzed and compared with bone on the contralateral side of the mandible after 4 weeks of consolidation. Results: The reconstructed defect was bridged with new bone, with little bone in the control defect. Regenerate density and microhardness were 22.3% and 42.6%, respectively, lower than the contralateral normal bone. Likewise, the anisotropy of the experimental group was statistically lower than in the contralateral bone. Half the experimental animals showed nonunion at the docking site. Conclusion: The device was very stable and easy to install and activate. After 1 month of consolidation, the defect was bridged with new bone, with evidence of active bone formation. Regenerate bone was less mature than the control bone. Studies are underway to identify when the regenerate properties compare with normal bone and to identify methods to augment bone union at the docking site. © 2012 American Association of Oral and Maxillofacial Surgeons.
  • No hay miniatura disponible
    Ítem
    Compendium of M.Sc. publications on numerical estimation of effective properties of porous materials
    (Universidad EAFIT, 2014) Osorno Tejada, María Camila; Ruíz Salguero, Oscar Eduardo
  • No hay miniatura disponible
    Ítem
    Desarrollo de un sistema protésico para personas con amputación transfemoral en Colombia
    (Universidad EAFIT, 2006) Correal Franco, Sara; Palacio Delgado, Lía Judith; Salazar Gómez, Isabel Cristina; Torres Velásquez, Andrés; Correa Vélez, Santiago
  • No hay miniatura disponible
    Ítem
    Design and construction of a transducer for bite force registration.
    (ELSEVIER SCI LTD, 2009-05-29) Isaza JF; Throckmorton GS; Roldán SI; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)
    This study describes the development of a system for quantification of human biting forces by (1) determining the mechanical properties of an epoxy resin reinforced with carbon fiber, (2) establishing the transducer's optimal dimensions to accommodate teeth of various widths while minimizing transducer thickness, and (3) determining the optimal location of strain gages using a series of mechanical resistance and finite element (FE) analyses. The optimal strain gage location was defined as the position that produced the least difference in strain pattern when the load was applied by teeth with two different surface areas. The result is a 7.3-mm-thick transducer with a maximum load capacity beyond any expected maximum bite force (1500N). This system includes a graphic interface that easily allows acquisition and registration of bite force by any health-sciences or engineering professional.
  • No hay miniatura disponible
    Ítem
    Design and construction of a transducer for bite force registration.
    (ELSEVIER SCI LTD, 2009-05-29) Isaza JF; Throckmorton GS; Roldán SI; Universidad EAFIT. Departamento de Ingeniería de Diseño; Ingeniería de Diseño (GRID)
    This study describes the development of a system for quantification of human biting forces by (1) determining the mechanical properties of an epoxy resin reinforced with carbon fiber, (2) establishing the transducer's optimal dimensions to accommodate teeth of various widths while minimizing transducer thickness, and (3) determining the optimal location of strain gages using a series of mechanical resistance and finite element (FE) analyses. The optimal strain gage location was defined as the position that produced the least difference in strain pattern when the load was applied by teeth with two different surface areas. The result is a 7.3-mm-thick transducer with a maximum load capacity beyond any expected maximum bite force (1500N). This system includes a graphic interface that easily allows acquisition and registration of bite force by any health-sciences or engineering professional.
  • No hay miniatura disponible
    Ítem
    FE-simulations with a simplified model for open-cell porous materials: A Kelvin cell approach
    (IOS Press, 2019-01-01) Montoya-Zapata D.; Cortés C.; Ruiz-Salguero O.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Laboratorio CAD/CAM/CAE
    In in-silico estimation of mechanical properties of open (Kelvin) cell porous materials, the geometrical model is intractable due to the large number of finite elements generated. Such a limitation impedes the study of reasonable domains. VoXel or Boundary representations of the porous domain result in FEA data sets which do not pass the stage of mesh generation, even for very modest domains. Our method to overcome such limitations partially replaces geometrical minutiae with kinematical constraints imposed on cylindrical bars (i.e. Truss model). Our implemented method uses node position equality constraints augmented with rotation constraints at the joints. Such a method significantly reduces the computational expense of the model, allowing the study of domains of 103 Kelvin cells. The results of the tests executed show the accuracy and efficiency of the Truss model in the estimation of Young's modulus and Poisson's ratio when compared with current procedures. The method allows application for materials which depart from Kelvin Cell uniformity, since the Truss model admits general configurations. As the simulation is made possible by the Truss model, new challenges appear, such as the application to anisotropic materials and the automatic generation of the Truss model from actual foam scans (e.g. tomographies). © 2019 - IOS Press and the authors. All rights reserved.
  • No hay miniatura disponible
    Ítem
    Geometry simplification of open-cell porous materials for elastic deformation FEA
    (SPRINGER, 2019-01-01) Cortés C.; Osorno M.; Uribe D.; Steeb H.; Ruiz-Salguero O.; Barandiarán I.; Flórez J.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Laboratorio CAD/CAM/CAE
    Estimation of mechanical properties of porous materials is central for their medical and industrial application. However, the massive size of accurate boundary representations (B-Rep) of the foams makes the numerical estimations intractable. Even for small domain sizes, the mesh generation for finite element analysis (FEA) may not terminate. Current efforts for simulating porous materials use statistical predictions of the material structure. The simulated and actual materials present different geometry and topology, with consequences on the simulation results. To overcome these limitations, this manuscript presents a method, which (1) synthesizes an accurate truss abstraction from the raw geometry data, (2) executes efficient FEA simulations, and (3) processes nodal displacements to estimate apparent mechanical moduli of the porous material. The method addresses materials whose ligaments have circular cross-sections. The iso-surface present in the Computer Tomography (CT) scan of the porous material is used to synthesize a truss graph whose edges are truncated cones. Then, optimization and simplification methods are applied to produce a topologically and geometrically correct truss representation for the foam domain. Comparative FEA load simulations are conducted between the full B-Rep and truss representations of the material. The truss model proves to be significantly more efficient for FEA, departing from the Full B-Rep FEA by a maximum of 16% in the estimation of equivalent mechanical moduli. Geometric assessments such as porosity and Hausdorff distance confirm that the truss abstraction is a cost-effective one. Ongoing efforts concentrate on point set geometric algorithms for enforcement of standardized material testing. © 2018 Springer-Verlag London Ltd., part of Springer Nature
  • No hay miniatura disponible
    Ítem
    In vitro mechanical evaluation of mandibular bone transport devices
    (ASME, 2014-06-01) Zapata, Uriel; Watanabe, Ikuya; Opperman, Lynne A.; Dechow, Paul C.; Mulone, Timothy; Elsalanty, Mohammed E.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)
    Bone transport distraction osteogenesis (BTDO) is a surgical procedure that has been used over the last 30 years for the correction of segmental defects produced mainly by trauma and oncological resections. Application of BTDO has several clinical advantages over traditional surgical techniques. Over the past few years, several BTDO devices have been introduced to reconstruct mandibular bone defects. Based on the location and outline of the defect, each device requires a uniquely shaped reconstruction plate. To date, no biomechanical evaluations of mandibular BTDO devices have been reported in the literature. The present study evaluated the mechanical behavior of three different shaped prototypes of a novel mandibular bone transport reconstruction plate and its transport unit for the reconstruction of segmental bone defects of the mandible by using numerical models complemented with mechanical laboratory tests to characterize strength, fatigue, and stability. The strength test evaluated device failures under extreme loads and was complemented with optimization procedures to improve the biomechanical behavior of the devices. The responses of the prototypes were characterized to improve their design and identify weak and strong regions in order to avoid posterior device failure in clinical applications. Combinations of the numerical and mechanical laboratory results were used to compare and validate the models. In addition, the results remark the importance of reducing the number of animals used in experimental tests by increasing computational and in vitro trials. © VC 2014 by ASME.
  • No hay miniatura disponible
    Ítem
    In vitro mechanical evaluation of mandibular bone transport devices
    (ASME, 2014-06-01) Zapata, Uriel; Watanabe, Ikuya; Opperman, Lynne A.; Dechow, Paul C.; Mulone, Timothy; Elsalanty, Mohammed E.; Zapata, Uriel; Watanabe, Ikuya; Opperman, Lynne A.; Dechow, Paul C.; Mulone, Timothy; Elsalanty, Mohammed E.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de Ingeniería
    Bone transport distraction osteogenesis (BTDO) is a surgical procedure that has been used over the last 30 years for the correction of segmental defects produced mainly by trauma and oncological resections. Application of BTDO has several clinical advantages over traditional surgical techniques. Over the past few years, several BTDO devices have been introduced to reconstruct mandibular bone defects. Based on the location and outline of the defect, each device requires a uniquely shaped reconstruction plate. To date, no biomechanical evaluations of mandibular BTDO devices have been reported in the literature. The present study evaluated the mechanical behavior of three different shaped prototypes of a novel mandibular bone transport reconstruction plate and its transport unit for the reconstruction of segmental bone defects of the mandible by using numerical models complemented with mechanical laboratory tests to characterize strength, fatigue, and stability. The strength test evaluated device failures under extreme loads and was complemented with optimization procedures to improve the biomechanical behavior of the devices. The responses of the prototypes were characterized to improve their design and identify weak and strong regions in order to avoid posterior device failure in clinical applications. Combinations of the numerical and mechanical laboratory results were used to compare and validate the models. In addition, the results remark the importance of reducing the number of animals used in experimental tests by increasing computational and in vitro trials. © VC 2014 by ASME.
  • No hay miniatura disponible
    Ítem
    Inverse kinematics for upper limb compound movement estimation in exoskeleton-assisted rehabilitation
    (Hindawi Publishing Corp., 2016-05-16) Cortés, Camilo; De los Reyes-Guzmán, Ana; Scorza, Davide; Bertelsen, Álvaro; Carrasco, Eduardo; Gil-Agudo, Ángel; Ruíz-Salguero, Óscar; Flórez, Julián; Universidad EAFIT. Departamento de Ingeniería Mecánica; Laboratorio CAD/CAM/CAE
    Robot-Assisted Rehabilitation (RAR) is relevant for treating patients affected by nervous system injuries (e.g., stroke and spinal cord injury) -- The accurate estimation of the joint angles of the patient limbs in RAR is critical to assess the patient improvement -- The economical prevalent method to estimate the patient posture in Exoskeleton-based RAR is to approximate the limb joint angles with the ones of the Exoskeleton -- This approximation is rough since their kinematic structures differ -- Motion capture systems (MOCAPs) can improve the estimations, at the expenses of a considerable overload of the therapy setup -- Alternatively, the Extended Inverse Kinematics Posture Estimation (EIKPE) computational method models the limb and Exoskeleton as differing parallel kinematic chains -- EIKPE has been tested with single DOFmovements of the wrist and elbow joints -- This paper presents the assessment of EIKPEwith elbow-shoulder compoundmovements (i.e., object prehension) -- Ground-truth for estimation assessment is obtained from an optical MOCAP (not intended for the treatment stage) -- The assessment shows EIKPE rendering a good numerical approximation of the actual posture during the compoundmovement execution, especially for the shoulder joint angles -- This work opens the horizon for clinical studies with patient groups, Exoskeleton models, and movements types --
  • No hay miniatura disponible
    Ítem
    Material properties of mandibular cortical bone in the American alligator, Alligator mississippiensis
    (ELSEVIER SCIENCE INC, 2010-03-01) Zapata, Uriel; Metzger, Keith; Wang, Qian; Elsey, Ruth M.; Ross, Callum F.; Dechow, Paul C.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)
    This study reports the elastic material properties of cortical bone in the mandible of juvenile Alligator mississippiensis obtained by using an ultrasonic wave technique. The elastic modulus, the shear modulus, and Poisson's ratio were measured on 42 cylindrical Alligator bone specimens obtained from the lingual and facial surfaces of 4 fresh Alligator mandibles. The data suggest that the elastic properties of alligator mandibular cortical bone are similar to those found in mammals and are orthotropic. The properties most resemble those found in the cortex of mammalian postcranial long bones where the bone is most stiff in one direction and much less stiff in the two remaining orthogonal directions. This is different from cortical bone found in the mandibles of humans and some monkeys, where the bone has greatest stiffness in one direction, much less stiffness in another direction, and an intermediate amount in the third orthogonal direction. This difference suggests a relationship between levels of orthotropy and bending stress. The comparability of these elastic moduli to those of other vertebrates suggest that the high bone strain magnitudes recorded from the alligator mandible in vivo are not attributable to a lower stiffness of alligator mandibular bone. © 2009 Elsevier Inc.
  • No hay miniatura disponible
    Ítem
    Medisuite + Iplate Integration EAFIT & Ilimitada S.A.
    (Universidad EAFIT, 2010) Vásquez Tieck, Juan Camilo; Zehnder, Alexander
    Force plate or pressure plate analysis came as an innovative tool to biomechanics and sport medicine -- This allows engineers, scientists and doctors to virtually reconstruct the way a person steps while running or walking using a measuring system and a computer -- With this information they can calculate and analyze a whole set of variables and factors that characterize the step -- Then they are able to make corrections and/or optimizations, designing appropriate shoes and insoles for the patient -- The idea is to study and understand all the hardware and software implications of this process and all the components involved, and then propose an alternative solution -- This solution should have at least similar performance to existing systems -- It should increase the accuracy and/or the sampling frequency to obtain better results -- By the end, there should be a working prototype of a pressure measuring system and a mathematical model to govern it -- The costs of the system have to be lower than most of the systems in the market
  • No hay miniatura disponible
    Ítem
    A product design methodology implementing ergonomic's aspects in man-artefact-environment systems
    (2014-03-27) Osorio Gómez, Gilberto; Mejía Gutiérrez, Ricardo; Hoyos Ruíz, Johana; Martínez Cadavid, José Fernando; Universidad EAFIT. Departamento de Ingeniería de Diseño; Gilberto Osorio (gosoriog@eafit.edu.co); Ricardo Mejia (rmejiag@eafit.edu.co); Jose Fernando Martinez (jmartine@eafit.edu.co); Johana Hoyos (jhoyosr2@eafit.edu.co); Ingeniería de Diseño - GRID
    If an object, a system or an environment is destined to a human interaction, then the design must be based upon the physical and mental characteristic of that user -- That’s the reason why a methodology of design that gathers the Man – Artefact – Environment with physical and cognitive ergonomics has been developed; implementing a synergy structure of design methodologies and criteria centering the user as a prime element in every stage of product development; guarantying a major adaptation to the context, capacities and necessities of the person, in a way that improves the efficiency, safety and wellbeing of consumers
  • No hay miniatura disponible
    Ítem
    A survey on static and quasi-static finite element models of the human cervical spine
    (Springer-Verlag France, 2018-05-01) Suarez-Escobar M.; Rendon-Velez E.; Universidad EAFIT. Departamento de Ingeniería de Diseño; Ingeniería de Diseño (GRID)
    Finite element analyses are an important source of information on the biomechanical behaviour of the cervical spine; as well as an important tool in the design and evaluation of spinal instrumentation. This article presents a comprehensive survey of the finite element models of the cervical spine that have been used to study its pathological/nonpathological biomechanics under static/quasi-static loading conditions. Publications that met the inclusion criteria were analysed to extract parameters relative to model identification (e.g., spine segment, population, utility, limitations), model structure (e.g., loading/boundary conditions, anatomical structures, constitutive representation), simulation structure (e.g., software), verification (e.g., convergence) and validation (e.g., validated procedure/output, assumptions). Besides summarizing different modelling approaches with their associated parameters, this article outlines generalities and issues related to the obtainment of such models. The survey shows that authors often fail to report parameters that are critical for the reproducibility of results and that, even with fully reported parameters, these models are inherently difficult to replicate because they generally are patient-specific with their geometry based on data from in-house specimens/subjects. Overall, while the survey contributes to an understanding of the implications of following different modelling approaches and allows to take advantage of previously developed models, further research is required to improve the accuracy and utility of these models. © 2017, Springer-Verlag France SAS, part of Springer Nature.
  • «
  • 1 (current)
  • 2
  • »

Vigilada Mineducación

Universidad con Acreditación Institucional hasta 2026 - Resolución MEN 2158 de 2018

Software DSpace copyright © 2002-2025 LYRASIS

  • Configuración de cookies
  • Enviar Sugerencias