Energy efficient measures to reduce electrical energy use in commercial buildings in New York City
dc.contributor.advisor | Toro, Juan Carlos | |
dc.contributor.author | Flórez Toro, Catalina | |
dc.coverage.spatial | Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees | eng |
dc.creator.degree | Ingeniero Mecánico | spa |
dc.creator.email | cataflorez87@hotmail.com | spa |
dc.date.accessioned | 2016-05-26T17:07:57Z | |
dc.date.available | 2016-05-26T17:07:57Z | |
dc.date.issued | 2015 | |
dc.description.abstract | GEA Consulting Engineers, acting as the design engineers, was hired by the owner, East Village 207 Residential LLC2 for energy modeling for compliance with LEED NC V3 -- This report details the results of the energy simulation done with the 100% construction documents -- This report only refers to entities within the LEED3 project boundary -- The project consists of a new eight-story high-end residential condominium building with 81 units, as shown in illustration 1, and approximately 117,905 GSF, equivalent to 10,953.73 m2, is located at 211 E 13th Street in New York, NY -- The residential portion of the building will function 24-7 -- The design goal is to utilize energy efficient measures to reduce electrical energy use and aims to achieve LEED certification -- LEED EA Credit 14 requires a building to demonstrate a percentage improvement in the proposed building performance compared with the baseline building -- The Credit rewards 1 point for achieving 12% reduction in energy costs -- Additionally, the Credit rewards another point for each subsequent reduction of 2% in the building’s energy cost | spa |
dc.identifier.uri | http://hdl.handle.net/10784/8536 | |
dc.language.iso | spa | spa |
dc.publisher | Universidad EAFIT | spa |
dc.publisher.department | Escuela de Ingeniería. Departamento de Ingeniería Mecánica | spa |
dc.publisher.program | Ingeniería Mecánica | spa |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | eng |
dc.rights.local | Acceso abierto | spa |
dc.subject | Iluminación inteligente | spa |
dc.subject | Iluminación industrial | spa |
dc.subject | Iluminación LED | spa |
dc.subject | LED (Diodo emisor de luz) | spa |
dc.subject.keyword | Buildings - power supply | spa |
dc.subject.keyword | Electric power consumption | spa |
dc.subject.keyword | Electric power - conservation | spa |
dc.subject.keyword | Interior lighting | spa |
dc.subject.keyword | Energy efficiency | spa |
dc.subject.lemb | EDIFICIOS - ABASTECIMIENTO DE ENERGÍA | spa |
dc.subject.lemb | CONSUMO DE ENERGÍA ELÉCTRICA | spa |
dc.subject.lemb | CONSERVACIÓN DE LA ENERGÍA ELÉCTRICA | spa |
dc.subject.lemb | ILUMINACIÓN DE INTERIORES | spa |
dc.subject.lemb | RENDIMIENTO ENERGÉTICO | spa |
dc.title | Energy efficient measures to reduce electrical energy use in commercial buildings in New York City | spa |
dc.type | info:eu-repo/semantics/bachelorThesis | |
dc.type | bachelorThesis | eng |
dc.type.hasVersion | acceptedVersion | eng |
dc.type.local | Trabajo de grado | spa |
Archivos
Bloque original
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- Catalina_FlorezToro_2015_tesis.pdf
- Tamaño:
- 1.48 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Trabajo de grado
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 2.5 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: