Preliminary geothermal conceptual model at Dabeiba - Antioquia, Colombia

dc.contributor.advisorMarín Cerón, María Isabelspa
dc.contributor.authorMontoya Londoño, Nicolás
dc.contributor.authorParra Londoño, Maria Camila
dc.coverage.spatialMedellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees
dc.creator.degreeGeólogospa
dc.creator.emailnmonto13@eafit.edu.cospa
dc.creator.emailmparral@eafit.edu.cospa
dc.date.accessioned2020-05-15T19:57:26Z
dc.date.available2020-05-15T19:57:26Z
dc.date.issued2019
dc.descriptionEl sistema geotérmico de Dabeiba (DGS) corresponde a un “play” de carácter extensional localizado sobre el costado más occidental de la cordillera occidental, en la subregión del Urabá, Antioquia-Colombia; donde el flujo de calor ocurre a lo largo del sistema de fallas Dabeiba-Pueblo Rico. Dicho sistema estructural, pone en contacto litologías del Complejo Cañasgordas, la Formación Guineales y rocas del Complejo Santa Cecilia-La Equis de Este a Norte. La falla Chimurró de carácter normal, elevó el gradiente geotérmico del área, evidenciado en la presencia de tres fuentes hidrotermales: El manantial de Mohán, manantial Chobar y manantial Guineales. El DGS puede ser entendido a partir de la construcción de un modelo geotérmico conceptual basado en la caracterización estructural, hidrogeológica, hidrogeoquímica y termocronológica a partir de recopilación de información secundaria. Usando un modelo semi-distribuido de balance hídrico, se estimaron las zonas potenciales de recarga y la relación con las tendencias estructurales del área, asociando el potencial de infiltración que se presenta al Oeste de la zona como el responsable de la entrada de agua meteórica en el sistema, favoreciendo la formación de aguas sódico-cloruradas con una tendencia de mezcla evidenciada en los datos isotópicos. El modelo geotérmico conceptual interpreta el flujo de calor desde una fuente profunda asociada a procesos de advección isotérmica generados por la falla normal Chimurro, a lo largo de la Formación Guineales. Mediante el análisis de geotermómetros junto con los datos termocronológicos de baja temperatura ((U / Th) He en apatitos) en los sedimentos de la Formación Guineales, fue posible clasificar el DGS como un “play” de baja entalpía con una temperatura aproximada de 150 ± 30 ° C. Adicionalmente, se sugiere que los fluidos hidrotermales a lo largo de las redes de fallas de Chimuro pueden haber estado actuando desde 1.7 a 2 Ma hasta el presente.spa
dc.description.abstractThe Dabeiba geothermal system (DGS) corresponds to an extensional character “play”. It is located on the westernmost side of the western mountain range, in the subregion of Urabá, Antioquia-Colombia; where heat flow occurs along the Dabeiba-Pueblo Rico fault system. This structural system puts the Cañasgordas Complex lithology, the Guineal Formation and rocks from the Santa Cecilia-La Equis Complex in contact from East to North. The Chimurro fault, of normal character, raised the geothermal gradient of the area, evidenced in the presence of three hydrothermal sources: the Mohán spring, Chobar spring and Guineales spring. The DGS can be understood from the construction of a conceptual geothermal model based on structural, hydrogeological, hydrogeochemical and thermochronological characterization from the collection of secondary information. Using a semi-distributed water balance model, the potential recharge zones and the relationship with the structural trends of the area were estimated. This was done by identifying the infiltration potential to the West of the area as responsible for the entry of meteoric water into the system, favoring the formation of sodium-chlorinated waters with a tendency of mixing evidenced in the isotopic data. The conceptual geothermal model interprets the heat flow from a deep source associated with isothermal advection processes generated by the normal Chimurro fault, along the Guineal Formation. Through the analysis of geothermometers together with the low temperature thermochronological data ((U/Th) He in apatites) in the sediments of the Guineal Formation, it was possible to classify the DGS as a low enthalpy play with an approximate temperature of 150 ± 30 ° C. Additionally, it is suggested that hydrothermal fluids along the Chimurro fault networks may have been operating from 1.7 to 2 Ma until now.spa
dc.identifier.ddc622.15 M798
dc.identifier.urihttp://hdl.handle.net/10784/16120
dc.language.isospaspa
dc.publisherUniversidad EAFITspa
dc.publisher.departmentEscuela de Ciencias. Departamento de Geologíaspa
dc.publisher.placeMedellínspa
dc.publisher.programGeologíaspa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.localAcceso abiertospa
dc.subjectSistema geotérmico Dabeiba - Antioquiaspa
dc.subjectSistemas estructuralesspa
dc.subjectFlujo de calorspa
dc.subjectFuentes hidrotermalesspa
dc.subject.lembGEOFÍSICAspa
dc.subject.lembGEOLOGÍA - COLOMBIA - DABEIBA (ANTIOQUIA)spa
dc.subject.lembGEOLOGÍA APLICADAspa
dc.subject.lembHIDROGEOLOGÍAspa
dc.titlePreliminary geothermal conceptual model at Dabeiba - Antioquia, Colombiaspa
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.typebachelorThesiseng
dc.type.hasVersionacceptedVersioneng
dc.type.localTrabajo de gradospa

Archivos

Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
Nicolas_MontoyaLondoño_MariaCamila_ParraLondoño_2019.pdf
Tamaño:
3.38 MB
Formato:
Adobe Portable Document Format
Descripción:
Trabajo de grado
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
2.5 KB
Formato:
Item-specific license agreed upon to submission
Descripción: