Examinando por Materia "Activated carbon"
Mostrando 1 - 7 de 7
Resultados por página
Opciones de ordenación
Ítem A Comparative Assessment of Emerging Solvents and Adsorbents for Mitigating CO2 Emissions From the Industrial Sector by Using Molecular Modeling Tools(Frontiers Media S.A., 2020-01-01) Bahamon D.; Alkhatib I.I.I.; Alkhatib N.; Builes S.; Sinnokrot M.; Vega L.F.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Desarrollo y Diseño de ProcesosThe possibilities offered by molecular modeling tools to obtain relevant data at process conditions, while also gaining molecular insights on the techniques used for CO2 capture and separation, are presented here using selected case studies. Two different technologies, absorption with amine-based systems and adsorption on porous materials, were explored, using the molecular-based equation of state, soft-Statistical Associating Fluid Theory (SAFT), and Grand Canonical Monte Carlo simulations, respectively. The aqueous monoethanolamine (MEA) system was set as the benchmark for absorption and compared to the performance of 8 alternative amine-based systems, while 16 adsorbents belonging to different families (zeolites, metal–organic frameworks, amorphous silicas, and activated carbons), bare or functionalized with alkylamines, were investigated for the separation of CO2 by adsorption. In addition to obtaining molecular information on the CO2 capture process, the models were further used to examine the CO2 capture performance in terms of cyclic working capacity and energy index as key performance indicators, allowing the identification of promising systems that can improve the current ones to be further evaluated for separation in non-power industries. Results show that for the same total amine mass concentration, non-aqueous amine solvents have a 5–10% reduction in cyclic working capacity, and a 10–30% decrease in the energy index compared to their aqueous counterparts due to their lower heat of vaporization and specific heat capacity. In addition, M-MOF-74, NaX, and NaY structures present the best results for adsorption in temperature swing adsorption (TSA) processes. Similar values of energy requirements to those of amine-based systems (2–2.5 MJ kg CO2–1) were obtained for some of the adsorbent; however, the disadvantage of the TSA process versus absorption should be considered. These results confirm the reliability of molecular modeling as an attractive and valuable screening tool for CO2 capture and separation processes. © Copyright © 2020 Bahamon, Alkhatib, Alkhatib, Builes, Sinnokrot and Vega.Ítem Efficient treatment for textile wastewater through sequential electrocoagulation, electrochemical oxidation and adsorption processes: Optimization and toxicity assessment(Elsevier BV, 2020-01-01) GilPavas E.; Dobrosz-Gómez I.; Gómez-García M.-Á.; GilPavas E.; Dobrosz-Gómez I.; Gómez-García M.-Á.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)In this work, the sequential Electrocoagulation + Electro-oxidation + Activated carbon adsorption (EC + EO + AC) process was studied as an alternative for the treatment of an industrial textile wastewater (TWW) issuing from a manufacturing company located in Medellín (Colombia). The EC's and EO's operational conditions were optimized using a Box-Behnken experimental design, the Response Surface Methodology and a constrained nonlinear optimization algorithm in terms of organic matter degradation efficiency. The best performance for EC (i. e., dye removal = 94%, COD and TOC degradation of 45 and 40%, respectively) was obtained using Fe anode and Boron Doped Diamond (BDD) cathode, with current density, jEC, equals to 5 mA/cm2, pH = 9.3, 60 RPM and 10 min of electrolysis. After EC treatment, the effluent biodegradability (evaluated as the BOD5/COD ratio) increases from 0.14 to 0.23. Regrettably, EC was not effective for the removal of acute toxicity to Artemia salina since the treated effluent remained very toxic (100%). The treatment of EC's effluent by EO enhanced organic pollutant removal. For EC + EO sequential process, EO optimal operational conditions (jEO = 10 mA/cm2, pH = 3, 240 RPM, BDD as anode and Fe as cathode) allowed reduction of 100% of color, 88% of COD and 79% of TOC after 30 min of electrolysis. Moreover, the BOD5/COD ratio increased from 0.23 to 0.58; however, the treated effluent remained very toxic to the Artemia salina. Consequently, an activated carbon adsorption step was included to complete the treatment process. Thus, by coupling the EC + EO + AC process, effluent's acute toxicity decreased completely. From molecular weight distribution analysis, it was concluded that EC + EO was efficient in eliminating low molecular weight (< 5 kDa) compounds. Finally, the operation cost, which includes chemical reagents, electrodes, energy consumption, and sludge disposal, for the EC + EO + AC sequential process was estimated in 3.83 USD /m3. © 2020 Elsevier B.V.Ítem Efficient treatment for textile wastewater through sequential electrocoagulation, electrochemical oxidation and adsorption processes: Optimization and toxicity assessment(Elsevier BV, 2020-01-01) GilPavas E.; Dobrosz-Gómez I.; Gómez-García M.-Á.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Desarrollo y Diseño de ProcesosIn this work, the sequential Electrocoagulation + Electro-oxidation + Activated carbon adsorption (EC + EO + AC) process was studied as an alternative for the treatment of an industrial textile wastewater (TWW) issuing from a manufacturing company located in Medellín (Colombia). The EC's and EO's operational conditions were optimized using a Box-Behnken experimental design, the Response Surface Methodology and a constrained nonlinear optimization algorithm in terms of organic matter degradation efficiency. The best performance for EC (i. e., dye removal = 94%, COD and TOC degradation of 45 and 40%, respectively) was obtained using Fe anode and Boron Doped Diamond (BDD) cathode, with current density, jEC, equals to 5 mA/cm2, pH = 9.3, 60 RPM and 10 min of electrolysis. After EC treatment, the effluent biodegradability (evaluated as the BOD5/COD ratio) increases from 0.14 to 0.23. Regrettably, EC was not effective for the removal of acute toxicity to Artemia salina since the treated effluent remained very toxic (100%). The treatment of EC's effluent by EO enhanced organic pollutant removal. For EC + EO sequential process, EO optimal operational conditions (jEO = 10 mA/cm2, pH = 3, 240 RPM, BDD as anode and Fe as cathode) allowed reduction of 100% of color, 88% of COD and 79% of TOC after 30 min of electrolysis. Moreover, the BOD5/COD ratio increased from 0.23 to 0.58; however, the treated effluent remained very toxic to the Artemia salina. Consequently, an activated carbon adsorption step was included to complete the treatment process. Thus, by coupling the EC + EO + AC process, effluent's acute toxicity decreased completely. From molecular weight distribution analysis, it was concluded that EC + EO was efficient in eliminating low molecular weight (< 5 kDa) compounds. Finally, the operation cost, which includes chemical reagents, electrodes, energy consumption, and sludge disposal, for the EC + EO + AC sequential process was estimated in 3.83 USD /m3. © 2020 Elsevier B.V.Ítem ¡En la U estamos recuperando aguas residuales!(2020-12-01) Martinez Guerrero, Christian Alexander; Christian Alexander Martinez-Guerrero; Christian Alexander Martinez-Guerrero; GilPavas, Edison; Drobosz-Gomez, Izabela; Gómez-García, Miguel-Ángel; Procesos AmbientalesÍtem Optimization and toxicity assessment of a combined electrocoagulation, H2O2/Fe2+/UV and activated carbon adsorption for textile wastewater treatment(Elsevier, 2019-02-15) GilPavas, E; Dobrosz-Gomez, I; Gomez-Garcia, MA; GilPavas, E; Dobrosz-Gomez, I; Gomez-Garcia, MA; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)In this study, the potential application of sequential Electrocoagulation + Fenton (F) or Photo-Fenton (PF) + Active carbon adsorption (EC + F/PF + AC) processes were analyzed as alternatives for the treatment of an industrial textile wastewater resulting from an industrial facility located in Medellín (Colombia). In order to maximize the organic matter degradation, each step of the treatment was optimized using the Response Surface Methodology. At first, the optimal performance of EC was achieved with Fe electrodes operating at pH = 7, jEC = 10 mA/cm2 and 60 rpm, during 10 min of electrolysis. At these conditions, EC let to remove 94% of the dye's color, 56% of the COD and 54% of the TOC. Next, sequentially applied Fenton or photo-Fenton process (i.e., EC + F/PF), operating at the optimized conditions (pH = 4.3, [Fe2+] = 1.1 mM, [H2O2] = 9.7 mM, stirring velocity = 100 rpm and reaction time = 60 min.), improved the quality of the treated effluent. The EC + F let to achieve total color reduction, as well as COD and TOC removals of 72 and 75%, respectively. The EC + PF reached 100% of color, 76% of COD and 78% of TOC reductions. The EC + F/PF processes were more efficient than EC in elimination of low molecular weight (<5 kDa) compounds from wastewater. Moreover, the BOD5/COD ratio increased from 0.21 to 0.42 and from 0.21 to 0.46 using EC + F and EC + PF processes, respectively. However, EC + F/PF were not fully effective for the removal of acute toxicity to Artemia salina: 20% and 60% of reduction in toxicity using EC + F and EC + PF, respectively, comparing to very toxic (100%) raw textile wastewater. Thus, activated carbon adsorption was applied as an additional step to complete the treatment. After AC adsorption, the acute toxicity decreased to 10% and 0% using EC + F and EC + PF, respectively. The total operational costs, including chemical reagents, electrodes, energy consumption and sludge disposal, were of 1.65 USD/m3 and 2.3 USD/m3 for EC + F and EC + PF, respectively. © 2018 Elsevier B.V.Ítem Optimization and toxicity assessment of a combined electrocoagulation, H2O2/Fe2+/UV and activated carbon adsorption for textile wastewater treatment(Elsevier, 2019-02-15) GilPavas, E; Dobrosz-Gomez, I; Gomez-Garcia, MA; Universidad EAFIT. Departamento de Ingeniería de Procesos; Desarrollo y Diseño de ProcesosIn this study, the potential application of sequential Electrocoagulation + Fenton (F) or Photo-Fenton (PF) + Active carbon adsorption (EC + F/PF + AC) processes were analyzed as alternatives for the treatment of an industrial textile wastewater resulting from an industrial facility located in Medellín (Colombia). In order to maximize the organic matter degradation, each step of the treatment was optimized using the Response Surface Methodology. At first, the optimal performance of EC was achieved with Fe electrodes operating at pH = 7, jEC = 10 mA/cm2 and 60 rpm, during 10 min of electrolysis. At these conditions, EC let to remove 94% of the dye's color, 56% of the COD and 54% of the TOC. Next, sequentially applied Fenton or photo-Fenton process (i.e., EC + F/PF), operating at the optimized conditions (pH = 4.3, [Fe2+] = 1.1 mM, [H2O2] = 9.7 mM, stirring velocity = 100 rpm and reaction time = 60 min.), improved the quality of the treated effluent. The EC + F let to achieve total color reduction, as well as COD and TOC removals of 72 and 75%, respectively. The EC + PF reached 100% of color, 76% of COD and 78% of TOC reductions. The EC + F/PF processes were more efficient than EC in elimination of low molecular weight (<5 kDa) compounds from wastewater. Moreover, the BOD5/COD ratio increased from 0.21 to 0.42 and from 0.21 to 0.46 using EC + F and EC + PF processes, respectively. However, EC + F/PF were not fully effective for the removal of acute toxicity to Artemia salina: 20% and 60% of reduction in toxicity using EC + F and EC + PF, respectively, comparing to very toxic (100%) raw textile wastewater. Thus, activated carbon adsorption was applied as an additional step to complete the treatment. After AC adsorption, the acute toxicity decreased to 10% and 0% using EC + F and EC + PF, respectively. The total operational costs, including chemical reagents, electrodes, energy consumption and sludge disposal, were of 1.65 USD/m3 and 2.3 USD/m3 for EC + F and EC + PF, respectively. © 2018 Elsevier B.V.Ítem ¿Sabías que en la U se están recuperando aguas residuales?(2020-12-01) Martinez Guerrero, Christian Alexander; Christian Alexander Martinez-Guerrero; GilPavas, Edison; Drobosz-Gomez, Izabela; Gómez-García, Miguel-Ángel; Vicerrectoría de Descubrimiento y Creación