Examinando por Autor "Dechow, Paul C."
Mostrando 1 - 8 de 8
Resultados por página
Opciones de ordenación
Ítem Architecture and microstructure of cortical bone in reconstructed canine mandibles after bone transport distraction osteogenesis(SPRINGER, 2011-11-01) Zapata, Uriel; Halvachs, Emily K.; Dechow, Paul C.; Elsalanty, Mohammed E.; Opperman, Lynne A.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)Reconstruction of the canine mandible using bone transport distraction osteogenesis has been shown to be a suitable method for correcting segmental bone defects produced by cancer, gunshots, and trauma. Although the mechanical quality of the new regenerate cortical bone seems to be related to the mineralization process, several questions regarding the microstructural patterns of the new bony tissue remain unanswered. The purpose of this study was to quantify any microstructural differences that may exist between the regenerate and control cortical bone. Five adult American foxhound dogs underwent unilateral bone transport distraction of the mandible to repair bone defects of 30-35 mm. Animals were killed 12 weeks after the beginning of the consolidation period. Fourteen cylindrical cortical samples were extracted from the superior, medial, and inferior aspects of the lingual and buccal plates of the reconstructed aspect of the mandible, and 21 specimens were collected similarly from the contralateral aspect of the mandible. Specimens were evaluated using histomorphometric and micro-computed tomographic techniques to compare their microstructure. Except for differences in haversian canal area, histomorphometric analyses suggested no statistical differences in microstructure between regenerate and control cortical bone. Morphological evaluation suggested a consistent level of anisotropy, possibly related to the distraction vector. After 12 weeks' consolidation, bone created during bone transport distraction osteogenesis was comparable to native bone in microstructure, architecture, and mechanical properties. It is proposed that, after enough time, the properties of the regenerate bone will be identical to that of native bone. © Springer Science+Business Media, LLC 2010.Ítem Architecture and microstructure of cortical bone in reconstructed canine mandibles after bone transport distraction osteogenesis(SPRINGER, 2011-11-01) Zapata, Uriel; Halvachs, Emily K.; Dechow, Paul C.; Elsalanty, Mohammed E.; Opperman, Lynne A.; Zapata, Uriel; Halvachs, Emily K.; Dechow, Paul C.; Elsalanty, Mohammed E.; Opperman, Lynne A.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaReconstruction of the canine mandible using bone transport distraction osteogenesis has been shown to be a suitable method for correcting segmental bone defects produced by cancer, gunshots, and trauma. Although the mechanical quality of the new regenerate cortical bone seems to be related to the mineralization process, several questions regarding the microstructural patterns of the new bony tissue remain unanswered. The purpose of this study was to quantify any microstructural differences that may exist between the regenerate and control cortical bone. Five adult American foxhound dogs underwent unilateral bone transport distraction of the mandible to repair bone defects of 30-35 mm. Animals were killed 12 weeks after the beginning of the consolidation period. Fourteen cylindrical cortical samples were extracted from the superior, medial, and inferior aspects of the lingual and buccal plates of the reconstructed aspect of the mandible, and 21 specimens were collected similarly from the contralateral aspect of the mandible. Specimens were evaluated using histomorphometric and micro-computed tomographic techniques to compare their microstructure. Except for differences in haversian canal area, histomorphometric analyses suggested no statistical differences in microstructure between regenerate and control cortical bone. Morphological evaluation suggested a consistent level of anisotropy, possibly related to the distraction vector. After 12 weeks' consolidation, bone created during bone transport distraction osteogenesis was comparable to native bone in microstructure, architecture, and mechanical properties. It is proposed that, after enough time, the properties of the regenerate bone will be identical to that of native bone. © Springer Science+Business Media, LLC 2010.Ítem Biomechanical characteristics of regenerated cortical bone in the canine mandible(WILEY-BLACKWELL, 2011-07-01) Zapata, Uriel; Opperman, Lynne A.; Kontogiorgos, Elias; Elsalanty, Mohammed E.; Dechow, Paul C.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)To test the mechanical properties of regenerate cortical bone created using mandibular bone transport (MBT) distraction, five adult male American foxhound dogs underwent unilateral distraction of the mandible with a novel MBT device placed to linearly repair a 30-35 mm bone defect. The animals were sacrificed 12 weeks after the beginning of the consolidation period. Fourteen cylindrical specimens were taken from the inner (lingual) and outer (buccal) plates of the reconstructed mandible and 21 control specimens were removed from the contralateral aspect of the mandible. The mechanical properties of the 35 cylindrical cortical bone specimens were assessed by using a non-destructive pulse ultrasound technique. Results showed that all of the cortical mechanical properties exhibit higher numerical values on the control side than the MBT regenerate side. In addition, both densities and the elastic moduli in the direction of maximum stiffness of the regenerate cortical bone specimens are higher on the lingual side than the buccal side. Interestingly, there is no statistical difference between elastic modulus (E1 and E2) in orthogonal directions throughout the 35 cortical specimens. The data suggest that not only is the regenerate canine cortical bone heterogeneous, but the elastic mechanical properties tend to approximate transverse isotropy at a tissue level, as opposed to control cortical bone, which is orthotropic. In addition, the elastic mechanical properties are higher not only on the control side but also in the lingual anatomical position, suggesting a stress shielding effect from the presence of the reconstruction plate. © 2011 John Wiley & Sons, Ltd.Ítem Biomechanics of the canine mandible during bone transport distraction osteogenesis(ASME, 2014-11-01) Zapata, Uriel; Dechow, Paul C.; Watanabe, Ikuya; Elsalanty, Mohammed E.; Opperman, Lynne A.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)This study compared biomechanical patterns between finite element models (FEMs) and a fresh dog mandible tested under molar and incisal physiological loads in order to clarify the effect of the bone transport distraction osteogenesis (BTDO) surgical process. Three FEMs of dog mandibles were built in order to evaluate the effects of BTDO. The first model evaluated the mandibular response under two physiological loads resembling bite processes. In the second model, a 5.0 cm bone defect was bridged with a bone transport reconstruction plate (BTRP). In the third model, new regenerated bony tissue was incorporated within the defect to mimic the surgical process without the presence of the device. Complementarily, a mandible of a male American foxhound dog was mechanically tested in the laboratory both in the presence and absence of a BTRP, and mechanical responses were measured by attaching rosettes to the bone surface of the mandible to validate the FEM predictions. The relationship between real and predicted values indicates that the stress patterns calculated using FEM are a valid predictor of the biomechanics of the BTDO procedures. The present study provides an interesting correlation between the stiffness of the device and the biomechanical response of the mandible affected for bone transport. Copyright © 2014 by ASME.Ítem Biomechanics of the canine mandible during bone transport distraction osteogenesis(ASME, 2014-11-01) Zapata, Uriel; Dechow, Paul C.; Watanabe, Ikuya; Elsalanty, Mohammed E.; Opperman, Lynne A.; Zapata, Uriel; Dechow, Paul C.; Watanabe, Ikuya; Elsalanty, Mohammed E.; Opperman, Lynne A.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaThis study compared biomechanical patterns between finite element models (FEMs) and a fresh dog mandible tested under molar and incisal physiological loads in order to clarify the effect of the bone transport distraction osteogenesis (BTDO) surgical process. Three FEMs of dog mandibles were built in order to evaluate the effects of BTDO. The first model evaluated the mandibular response under two physiological loads resembling bite processes. In the second model, a 5.0 cm bone defect was bridged with a bone transport reconstruction plate (BTRP). In the third model, new regenerated bony tissue was incorporated within the defect to mimic the surgical process without the presence of the device. Complementarily, a mandible of a male American foxhound dog was mechanically tested in the laboratory both in the presence and absence of a BTRP, and mechanical responses were measured by attaching rosettes to the bone surface of the mandible to validate the FEM predictions. The relationship between real and predicted values indicates that the stress patterns calculated using FEM are a valid predictor of the biomechanics of the BTDO procedures. The present study provides an interesting correlation between the stiffness of the device and the biomechanical response of the mandible affected for bone transport. Copyright © 2014 by ASME.Ítem In vitro mechanical evaluation of mandibular bone transport devices(ASME, 2014-06-01) Zapata, Uriel; Watanabe, Ikuya; Opperman, Lynne A.; Dechow, Paul C.; Mulone, Timothy; Elsalanty, Mohammed E.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)Bone transport distraction osteogenesis (BTDO) is a surgical procedure that has been used over the last 30 years for the correction of segmental defects produced mainly by trauma and oncological resections. Application of BTDO has several clinical advantages over traditional surgical techniques. Over the past few years, several BTDO devices have been introduced to reconstruct mandibular bone defects. Based on the location and outline of the defect, each device requires a uniquely shaped reconstruction plate. To date, no biomechanical evaluations of mandibular BTDO devices have been reported in the literature. The present study evaluated the mechanical behavior of three different shaped prototypes of a novel mandibular bone transport reconstruction plate and its transport unit for the reconstruction of segmental bone defects of the mandible by using numerical models complemented with mechanical laboratory tests to characterize strength, fatigue, and stability. The strength test evaluated device failures under extreme loads and was complemented with optimization procedures to improve the biomechanical behavior of the devices. The responses of the prototypes were characterized to improve their design and identify weak and strong regions in order to avoid posterior device failure in clinical applications. Combinations of the numerical and mechanical laboratory results were used to compare and validate the models. In addition, the results remark the importance of reducing the number of animals used in experimental tests by increasing computational and in vitro trials. © VC 2014 by ASME.Ítem In vitro mechanical evaluation of mandibular bone transport devices(ASME, 2014-06-01) Zapata, Uriel; Watanabe, Ikuya; Opperman, Lynne A.; Dechow, Paul C.; Mulone, Timothy; Elsalanty, Mohammed E.; Zapata, Uriel; Watanabe, Ikuya; Opperman, Lynne A.; Dechow, Paul C.; Mulone, Timothy; Elsalanty, Mohammed E.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaBone transport distraction osteogenesis (BTDO) is a surgical procedure that has been used over the last 30 years for the correction of segmental defects produced mainly by trauma and oncological resections. Application of BTDO has several clinical advantages over traditional surgical techniques. Over the past few years, several BTDO devices have been introduced to reconstruct mandibular bone defects. Based on the location and outline of the defect, each device requires a uniquely shaped reconstruction plate. To date, no biomechanical evaluations of mandibular BTDO devices have been reported in the literature. The present study evaluated the mechanical behavior of three different shaped prototypes of a novel mandibular bone transport reconstruction plate and its transport unit for the reconstruction of segmental bone defects of the mandible by using numerical models complemented with mechanical laboratory tests to characterize strength, fatigue, and stability. The strength test evaluated device failures under extreme loads and was complemented with optimization procedures to improve the biomechanical behavior of the devices. The responses of the prototypes were characterized to improve their design and identify weak and strong regions in order to avoid posterior device failure in clinical applications. Combinations of the numerical and mechanical laboratory results were used to compare and validate the models. In addition, the results remark the importance of reducing the number of animals used in experimental tests by increasing computational and in vitro trials. © VC 2014 by ASME.Ítem Material properties of mandibular cortical bone in the American alligator, Alligator mississippiensis(ELSEVIER SCIENCE INC, 2010-03-01) Zapata, Uriel; Metzger, Keith; Wang, Qian; Elsey, Ruth M.; Ross, Callum F.; Dechow, Paul C.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)This study reports the elastic material properties of cortical bone in the mandible of juvenile Alligator mississippiensis obtained by using an ultrasonic wave technique. The elastic modulus, the shear modulus, and Poisson's ratio were measured on 42 cylindrical Alligator bone specimens obtained from the lingual and facial surfaces of 4 fresh Alligator mandibles. The data suggest that the elastic properties of alligator mandibular cortical bone are similar to those found in mammals and are orthotropic. The properties most resemble those found in the cortex of mammalian postcranial long bones where the bone is most stiff in one direction and much less stiff in the two remaining orthogonal directions. This is different from cortical bone found in the mandibles of humans and some monkeys, where the bone has greatest stiffness in one direction, much less stiffness in another direction, and an intermediate amount in the third orthogonal direction. This difference suggests a relationship between levels of orthotropy and bending stress. The comparability of these elastic moduli to those of other vertebrates suggest that the high bone strain magnitudes recorded from the alligator mandible in vivo are not attributable to a lower stiffness of alligator mandibular bone. © 2009 Elsevier Inc.