Artículos (Gema)
URI permanente para esta colección
Examinar
Examinando Artículos (Gema) por Autor "Arroyave, M."
Mostrando 1 - 3 de 3
Resultados por página
Opciones de ordenación
Ítem Diseño e implementación de un reactor PECVD para producir películas delgadas a partir de un horno microondas casero(Universidad de Tarapaca, 2015-01-01) Arroyave, M.; Ocampo, J.M.J.; Arenas, Monica; Jaramillo, Juliana; saldarriaga, Clarita; Londoño, Valentina; Universidad EAFIT. Departamento de Ciencias Básicas; Electromagnetismo Aplicado (Gema)El presente trabajo describe el desarrollo y la implementación de un reactor de deposición química de vapor asistido por plasma PECVD (Plasma Enhanced Chemical Vapor Deposition). La construcción se realizó a partir del diseño de los diferentes componentesÍtem Implementation of a preamplifier-amplifier system for radiation detectors used in Mössbauer spectroscopy(SPRINGER, 2014-01-01) Velasquez, A. A.; Arroyave, M.; Universidad EAFIT. Departamento de Ciencias Básicas; Electromagnetismo Aplicado (Gema)We report the assembly and testing of a preamplification and amplification system for pulses produced by gaseous radiation detectors commonly used in Mössbauer spectroscopy. The system is composed by a pair of commercial integrated circuits A203 and A206, which operate as charge sensitive preamplifier-shaping amplifier and linear amplifier-low level discriminator, respectively. The integrated circuits were interconnected in the unipolar output mode and placed inside a metallic shielding, which prevents noise amplification for a suitable signal-noise ratio. The system was tested by irradiating a proportional counter LND-45431 with characteristic X rays of 6.3 keV and gamma rays of 14.4 keV emitted by a Mössbauer radioactive source of 57Co (Rh). Unipolar pulses with Gaussian profile were obtained at the output of the linear amplifier, whose amplitudes were close to 0.4 V for 6.3 keV X rays and 1.4 V for 14.4 keV gamma rays. Pulse height spectra showed that the system allows a satisfactory identification of the X-rays and gamma rays emitted by the 57Co source, giving the possibility to make a good selection of the 14.4 keV peak for having a suitable signal-noise ratio in the Mössbauer spectra. Absorption percentages of 14 % were found by taking the Mössbauer spectra of a natural iron absorber. The assembly and tests of the system are presented through this paper. © 2013 Springer Science+Business Media Dordrecht.Ítem Laboratorios remotos: Diversos escenarios de trabajo(Universidad de Los Andes, 2011-12-01) Arroyave, M.; Velásquez, A. A.; Olarte, Tomás; Montoya, Juan Carlos; Universidad EAFIT. Departamento de Ciencias Básicas; Electromagnetismo Aplicado (Gema)Los laboratorios como lugares de experimentación son una herramienta de gran importancia en la educación y la investigación, ya que permiten entender mejor los conceptos y también permiten construir nuevo conocimiento. Sin embargo contar con laboratorios