Cement in-line calciner kiln modeling for heat optimization using a design of computer experiments

dc.contributor.advisorAcosta Maya, Diego Andrésspa
dc.contributor.authorOrtiz Muñoz, Alejandro
dc.contributor.authorBuiles Toro, Santiago
dc.contributor.authorAcosta Maya, Diego Andrés
dc.coverage.spatialMedellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degreeseng
dc.creator.degreeMagíster en Ingenieríaspa
dc.creator.emailaortiz@argos.com.cospa
dc.creator.emailsbuiles@eafit.edu.cospa
dc.creator.emaildacostam@eafit.edu.cospa
dc.creator.grantorCementos Argos S.A. Zona Franca Argos S.A.S.spa
dc.date.accessioned2021-01-29T17:54:12Z
dc.date.available2021-01-29T17:54:12Z
dc.date.issued2020
dc.descriptionSe implementó un modelo de un horno de cemento de proceso seco con calcinador en línea en Aspen Plus V9 y se validó con datos de un horno de cemento calcinador en línea de 2000 toneladas por día. Se obtuvo un modelo simplificado del proceso utilizando un diseño de experimentos Plackett-Burman de 20 corridas en simulaciones de Aspen Plus con 19 variables de entrada relacionadas con entradas de aire falso, concentración de oxígeno, temperatura del calcinador, eficiencia de ciclones y la altura de la cama del clínker en el enfriador. Se obtuvieron metamodelos lineales para el consumo específico calórico (CEC) y otras variables de respuesta. El metamodelo indicó que (i) el aire falso en los ciclones 4 y 5, (ii) la temperatura de control del calcinador, (iii) la concentración de oxígeno en la salida del calcinador y (iv) la altura del lecho de clínker en el enfriador fueron las variables de entrada más importantes que afectaron al CEC . El CEC obtenido de la simulación basada en los valores optimizados del metamodelo resultó en una reducción de ca. 29 kcal / kg de clínker. Un análisis de sensibilidad indicó que las dos variables más impactantes fueron la concentración de oxígeno a la salida del calcinador y la altura de la cama de clínker en el enfriador. El metamodelo del CEC es una herramienta poderosa para capturar la complejidad de las simulaciones de procesos en un modelo simple y fácil de usar.spa
dc.description.abstractA model of a dry process cement kiln was implemented in Aspen Plus V9 and validated with a 2000 metric ton per day in-line calciner cement kiln data. A simpli ed model of the process was obtained using a 20-run Plackett-Burman design of experiments on Aspen Plus simulations with 19 input variables related to false air (in-leakage air), oxygen concentration, calciner temperature, cyclones e ciency and clinker's cooler bed height. Linear metamodels for the speci c heat consumption (SHC) and other response variables were obtained. The metamodel indicated that (i) false air in cyclones 4 and 5, (ii) calciner's control temperature, (iii) oxygen concentration at the calciner exit and (iv) cooler's clinker bed height were the most signi cant input variables a ecting SHC. The SHC obtained from simulation based on the optimized values from the metamodel resulted in a reduction of ca. 29 kcal/kg of clinker. A sensitivity analysis indicated that the two most impacting variables were the oxygen concentration at the calciner's exit and the cooler's clinker bed depth. The SHC metamodel is a powerful tool for capturing the complexity of the process simulations on a simple and easy to use model.spa
dc.formatapplication/pdfeng
dc.identifier.ddc620.135 O775
dc.identifier.urihttp://hdl.handle.net/10784/25460
dc.language.isospaspa
dc.publisherUniversidad EAFITspa
dc.publisher.departmentEscuela de Ingenieríaspa
dc.publisher.placeMedellínspa
dc.publisher.programMaestría en Ingenieríaspa
dc.rightsTodos los derechos reservadosspa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.localAcceso abiertospa
dc.subjectHorno de cementospa
dc.subjectSimulación en Aspen Plusspa
dc.subjectOptimización de calorspa
dc.subjectModelo de clinkerspa
dc.subjectMetamodelo linealspa
dc.subjectDiseño de experimentos por computadorspa
dc.subject.keywordCement pre-calciner kilnspa
dc.subject.keywordDesign of computer experimentsspa
dc.subject.keywordAspen Plus simulationspa
dc.subject.keywordHeat optimizationspa
dc.subject.keywordClinker modelspa
dc.subject.keywordLinear meta-modelspa
dc.subject.lembINGENIERÍA DE LA PRODUCCIÓNspa
dc.subject.lembMATERIALES DE CONSTRUCCIÓNspa
dc.subject.lembCOMPUESTOS CEMENTOSOSspa
dc.titleCement in-line calciner kiln modeling for heat optimization using a design of computer experimentsspa
dc.typemasterThesiseng
dc.typeinfo:eu-repo/semantics/masterThesiseng
dc.type.hasVersionacceptedVersioneng
dc.type.localTesis de Maestríaspa

Archivos

Bloque original
Mostrando 1 - 3 de 3
No hay miniatura disponible
Nombre:
aprobacion_trabajo_grado_eafit.pdf
Tamaño:
69.06 KB
Formato:
Adobe Portable Document Format
Descripción:
Carta de aprobación de tesis de grado
No hay miniatura disponible
Nombre:
formulario_autorizacion_publicacion_obras.pdf
Tamaño:
794.11 KB
Formato:
Adobe Portable Document Format
Descripción:
Formulario de autorización de publicación de obras
No hay miniatura disponible
Nombre:
Alejandro_OrtizMunoz_Santiago_BuilesToro_DiegosAndres_AcostaMaya_2020.pdf
Tamaño:
663.98 KB
Formato:
Adobe Portable Document Format
Descripción:
Trabajo de grado
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
2.5 KB
Formato:
Item-specific license agreed upon to submission
Descripción: