Cement in-line calciner kiln modeling for heat optimization using a design of computer experiments
dc.contributor.advisor | Acosta Maya, Diego Andrés | spa |
dc.contributor.author | Ortiz Muñoz, Alejandro | |
dc.contributor.author | Builes Toro, Santiago | |
dc.contributor.author | Acosta Maya, Diego Andrés | |
dc.coverage.spatial | Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees | eng |
dc.creator.degree | Magíster en Ingeniería | spa |
dc.creator.email | aortiz@argos.com.co | spa |
dc.creator.email | sbuiles@eafit.edu.co | spa |
dc.creator.email | dacostam@eafit.edu.co | spa |
dc.creator.grantor | Cementos Argos S.A. Zona Franca Argos S.A.S. | spa |
dc.date.accessioned | 2021-01-29T17:54:12Z | |
dc.date.available | 2021-01-29T17:54:12Z | |
dc.date.issued | 2020 | |
dc.description | Se implementó un modelo de un horno de cemento de proceso seco con calcinador en línea en Aspen Plus V9 y se validó con datos de un horno de cemento calcinador en línea de 2000 toneladas por día. Se obtuvo un modelo simplificado del proceso utilizando un diseño de experimentos Plackett-Burman de 20 corridas en simulaciones de Aspen Plus con 19 variables de entrada relacionadas con entradas de aire falso, concentración de oxígeno, temperatura del calcinador, eficiencia de ciclones y la altura de la cama del clínker en el enfriador. Se obtuvieron metamodelos lineales para el consumo específico calórico (CEC) y otras variables de respuesta. El metamodelo indicó que (i) el aire falso en los ciclones 4 y 5, (ii) la temperatura de control del calcinador, (iii) la concentración de oxígeno en la salida del calcinador y (iv) la altura del lecho de clínker en el enfriador fueron las variables de entrada más importantes que afectaron al CEC . El CEC obtenido de la simulación basada en los valores optimizados del metamodelo resultó en una reducción de ca. 29 kcal / kg de clínker. Un análisis de sensibilidad indicó que las dos variables más impactantes fueron la concentración de oxígeno a la salida del calcinador y la altura de la cama de clínker en el enfriador. El metamodelo del CEC es una herramienta poderosa para capturar la complejidad de las simulaciones de procesos en un modelo simple y fácil de usar. | spa |
dc.description.abstract | A model of a dry process cement kiln was implemented in Aspen Plus V9 and validated with a 2000 metric ton per day in-line calciner cement kiln data. A simpli ed model of the process was obtained using a 20-run Plackett-Burman design of experiments on Aspen Plus simulations with 19 input variables related to false air (in-leakage air), oxygen concentration, calciner temperature, cyclones e ciency and clinker's cooler bed height. Linear metamodels for the speci c heat consumption (SHC) and other response variables were obtained. The metamodel indicated that (i) false air in cyclones 4 and 5, (ii) calciner's control temperature, (iii) oxygen concentration at the calciner exit and (iv) cooler's clinker bed height were the most signi cant input variables a ecting SHC. The SHC obtained from simulation based on the optimized values from the metamodel resulted in a reduction of ca. 29 kcal/kg of clinker. A sensitivity analysis indicated that the two most impacting variables were the oxygen concentration at the calciner's exit and the cooler's clinker bed depth. The SHC metamodel is a powerful tool for capturing the complexity of the process simulations on a simple and easy to use model. | spa |
dc.format | application/pdf | eng |
dc.identifier.ddc | 620.135 O775 | |
dc.identifier.uri | http://hdl.handle.net/10784/25460 | |
dc.language.iso | spa | spa |
dc.publisher | Universidad EAFIT | spa |
dc.publisher.department | Escuela de Ingeniería | spa |
dc.publisher.place | Medellín | spa |
dc.publisher.program | Maestría en Ingeniería | spa |
dc.rights | Todos los derechos reservados | spa |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
dc.rights.local | Acceso abierto | spa |
dc.subject | Horno de cemento | spa |
dc.subject | Simulación en Aspen Plus | spa |
dc.subject | Optimización de calor | spa |
dc.subject | Modelo de clinker | spa |
dc.subject | Metamodelo lineal | spa |
dc.subject | Diseño de experimentos por computador | spa |
dc.subject.keyword | Cement pre-calciner kiln | spa |
dc.subject.keyword | Design of computer experiments | spa |
dc.subject.keyword | Aspen Plus simulation | spa |
dc.subject.keyword | Heat optimization | spa |
dc.subject.keyword | Clinker model | spa |
dc.subject.keyword | Linear meta-model | spa |
dc.subject.lemb | INGENIERÍA DE LA PRODUCCIÓN | spa |
dc.subject.lemb | MATERIALES DE CONSTRUCCIÓN | spa |
dc.subject.lemb | COMPUESTOS CEMENTOSOS | spa |
dc.title | Cement in-line calciner kiln modeling for heat optimization using a design of computer experiments | spa |
dc.type | masterThesis | eng |
dc.type | info:eu-repo/semantics/masterThesis | eng |
dc.type.hasVersion | acceptedVersion | eng |
dc.type.local | Tesis de Maestría | spa |
Archivos
Bloque original
1 - 3 de 3
No hay miniatura disponible
- Nombre:
- aprobacion_trabajo_grado_eafit.pdf
- Tamaño:
- 69.06 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Carta de aprobación de tesis de grado
No hay miniatura disponible
- Nombre:
- formulario_autorizacion_publicacion_obras.pdf
- Tamaño:
- 794.11 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Formulario de autorización de publicación de obras
No hay miniatura disponible
- Nombre:
- Alejandro_OrtizMunoz_Santiago_BuilesToro_DiegosAndres_AcostaMaya_2020.pdf
- Tamaño:
- 663.98 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Trabajo de grado
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 2.5 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: