Examinando por Materia "Young modulus"
Mostrando 1 - 6 de 6
Resultados por página
Opciones de ordenación
Ítem Biomechanical characteristics of regenerated cortical bone in the canine mandible(WILEY-BLACKWELL, 2011-07-01) Zapata, Uriel; Opperman, Lynne A.; Kontogiorgos, Elias; Elsalanty, Mohammed E.; Dechow, Paul C.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)To test the mechanical properties of regenerate cortical bone created using mandibular bone transport (MBT) distraction, five adult male American foxhound dogs underwent unilateral distraction of the mandible with a novel MBT device placed to linearly repair a 30-35 mm bone defect. The animals were sacrificed 12 weeks after the beginning of the consolidation period. Fourteen cylindrical specimens were taken from the inner (lingual) and outer (buccal) plates of the reconstructed mandible and 21 control specimens were removed from the contralateral aspect of the mandible. The mechanical properties of the 35 cylindrical cortical bone specimens were assessed by using a non-destructive pulse ultrasound technique. Results showed that all of the cortical mechanical properties exhibit higher numerical values on the control side than the MBT regenerate side. In addition, both densities and the elastic moduli in the direction of maximum stiffness of the regenerate cortical bone specimens are higher on the lingual side than the buccal side. Interestingly, there is no statistical difference between elastic modulus (E1 and E2) in orthogonal directions throughout the 35 cortical specimens. The data suggest that not only is the regenerate canine cortical bone heterogeneous, but the elastic mechanical properties tend to approximate transverse isotropy at a tissue level, as opposed to control cortical bone, which is orthotropic. In addition, the elastic mechanical properties are higher not only on the control side but also in the lingual anatomical position, suggesting a stress shielding effect from the presence of the reconstruction plate. © 2011 John Wiley & Sons, Ltd.Ítem Contributions of intermolecular bonding and lubrication to the mechanical behavior of a natural armor(ELSEVIER SCI LTD, 2020-01-01) Jiang, H.; Ghods, S.; Weller, E.; Waddell, S.; Ossa, E.A.; Yang, F.; Arola, D.; Jiang, H.; Ghods, S.; Weller, E.; Waddell, S.; Ossa, E.A.; Yang, F.; Arola, D.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaAmong many dermal armors, fish scales have become a source of inspiration in the pursuit of “next-generation” structural materials. Although fish scales function in a hydrated environment, the role of water and intermolecular hydrogen bonding to their unique structural behavior has not been elucidated. Water molecules reside within and adjacent to the interpeptide locations of the collagen fibrils of the elasmodine and provide lubrication to the protein molecules during deformation. We evaluated the contributions of this lubrication and the intermolecular bonding to the mechanical behavior of elasmodine scales from the Black Carp (Mylopharyngodon piceus). Scales were exposed to polar solvents, followed by axial loading to failure and the deformation mechanisms were characterized via optical mechanics. Displacement of intermolecular water molecules by liquid polar solvents caused significant (p = 0.05) increases in stiffness, strength and toughness of the scales. Removal of this lubrication decreased the capacity for non-linear deformation and toughness, which results from the increased resistance to fibril rotations and sliding caused by molecular friction. The intermolecular lubrication is a key component of the “protecto-flexibility” of scales and these natural armors as a system; it can serve as an important component of biomimetic-driven designs for flexible armor systems. Statement of Significance: The natural armor of fish has become a topic of substantial scientific interest. Hydration is important to these materials as water molecules reside within the interpeptide locations of the collagen fibrils of the elasmodine and provide lubrication to the protein molecules during deformation. We explored the opportunity for tuning the mechanical behavior of scales as a model for next-generation engineering materials by adjusting the extent of hydrogen bonding with polar solvents and the corresponding interpeptide molecular lubrication. Removal of this lubrication decreased the capacity for non-linear deformation and toughness due to an increase in resistance to fibril rotations and sliding as imparted by molecular friction. We show that intermolecular lubrication is a key component of the “protecto-flexibility” of natural armors and it is an essential element of biomimetic approaches to develop flexible armor systems. © 2020 Acta Materialia Inc.Ítem Effect of chemical composition and microstructure on the mechanical behavior of fish scales from Megalops Atlanticus(ELSEVIER SCIENCE BV, 2016-03-01) Gil-Duran, S.; Arola, D.; Ossa, E.A.; Gil-Duran, S.; Arola, D.; Ossa, E.A.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaThis paper presents an experimental study of the composition, microstructure and mechanical behavior of scales from the Megalops Atlanticus (Atlantic tarpon). The microstructure and composition were evaluated by Scanning Electron Microscopy (SEM) and RAMAN spectroscopy, respectively. The mechanical properties were evaluated in uniaxial tension as a function of position along the length of the fish (head, mid-length and tail). Results showed that the scales are composed of collagen and hydroxyapatite, and these constituents are distributed within three well-defined layers from the bottom to the top of the scale. The proportion of these layers with respect to the total scale thickness varies radially. The collagen fibers are arranged in plies with different orientations and with preferred orientation in the longitudinal direction of the fish. Results from the tensile tests showed that scales from Megalops Atlanticus exhibit variations in the elastic modulus as a function of body position. Additional testing performed with and without the highly mineralized top layers of the scale revealed that the mechanical behavior is anisotropic and that the highest strength was exhibited along the fish length. Furthermore, removing the top mineralized layers resulted in an increase in the tensile strength of the scale. © 2015 Elsevier Ltd.Ítem The global impact of sutures assessed in a finite element model of a macaque cranium(WILEY-LISS, 2010-09-01) Wang, Qian; Smith, Amanda L.; Strait, David S.; Wright, Barth W.; Richmond, Brian G.; Grosse, Ian R.; Byron, Craig D.; Zapata, Uriel; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)The biomechanical significance of cranial sutures in primates is an open question because their global impact is unclear, and their material properties are difficult to measure. In this study, eight suture-bone functional units representing eight facial sutures were created in a finite element model of a monkey cranium. All the sutures were assumed to have identical isotropic linear elastic material behavior that varied in different modeling experiments, representing either fused or unfused sutures. The values of elastic moduli employed in these trials ranged over several orders of magnitude. Each model was evaluated under incisor, premolar, and molar biting conditions. Results demonstrate that skulls with unfused sutures permitted more deformations and experienced higher total strain energy. However, strain patterns remained relatively unaffected away from the suture sites, and bite reaction force was likewise barely affected. These findings suggest that suture elasticity does not substantially alter load paths through the macaque skull or its underlying rigid body kinematics. An implication is that, for the purposes of finite element analysis, omitting or fusing sutures is a reasonable modeling approximation for skulls with small suture volume fraction if the research objective is to observe general patterns of craniofacial biomechanics under static loading conditions. The manner in which suture morphology and ossification affect the mechanical integrity of skulls and their ontogeny and evolution awaits further investigation, and their viscoelastic properties call for dynamic simulations. © 2010 Wiley-Liss, Inc.Ítem Material properties of mandibular cortical bone in the American alligator, Alligator mississippiensis(ELSEVIER SCIENCE INC, 2010-03-01) Zapata, Uriel; Metzger, Keith; Wang, Qian; Elsey, Ruth M.; Ross, Callum F.; Dechow, Paul C.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)This study reports the elastic material properties of cortical bone in the mandible of juvenile Alligator mississippiensis obtained by using an ultrasonic wave technique. The elastic modulus, the shear modulus, and Poisson's ratio were measured on 42 cylindrical Alligator bone specimens obtained from the lingual and facial surfaces of 4 fresh Alligator mandibles. The data suggest that the elastic properties of alligator mandibular cortical bone are similar to those found in mammals and are orthotropic. The properties most resemble those found in the cortex of mammalian postcranial long bones where the bone is most stiff in one direction and much less stiff in the two remaining orthogonal directions. This is different from cortical bone found in the mandibles of humans and some monkeys, where the bone has greatest stiffness in one direction, much less stiffness in another direction, and an intermediate amount in the third orthogonal direction. This difference suggests a relationship between levels of orthotropy and bending stress. The comparability of these elastic moduli to those of other vertebrates suggest that the high bone strain magnitudes recorded from the alligator mandible in vivo are not attributable to a lower stiffness of alligator mandibular bone. © 2009 Elsevier Inc.Ítem Zylerberg, 1985 Contributions of the layer topology and mineral content to the elastic modulus and strength of fish scales(ELSEVIER SCIENCE BV, 2018-02-01) Murcia, S.; Miyamoto, Y.; Varma, M.P.; Ossa, A.; Arola, D.Fish scales are an interesting natural structural material and their functionality requires both flexibility and toughness. Our previous studies identified that there are spatial variations in the elastic properties of fish scales corresponding to the anatomical regions, and that they appear to be attributed to changes in the microstructure. In the present study, a model is proposed that describes the elastic behavior of elasmoid fish scales in terms of the relative contributions of the limiting layer and both the internal and external elasmodine. The mechanical properties of scales from the Megalops atlanticus (i.e. tarpon) were characterized in tension and compared with predictions from the model. The average error between the predicted and the experimental properties was 7%. It was found that the gradient in mineral content and aspect ratio of the apatite crystals in the limiting layer played the most important roles on the elastic modulus of the scales. Furthermore, misalignment of plies in the external elasmodine from the longitudinal direction was shown to reduce the elastic modulus significantly. This is one approach for modulating the fish scale flexibility for a high mineral content that is required to increase the resistance to puncture. © 2017