Examinando por Materia "Parametric sensitivity analysis"
Mostrando 1 - 2 de 2
Resultados por página
Opciones de ordenación
Ítem Análisis de la sensibilidad paramétrica del proceso de producción de ciclo-trimetileno-triamina(Centro de Informacion Tecnologica, 2014-01-01) Ojeda, J.C.; Gilpavas, E.; Dobrosz-Gómez, I.; Gómez, M.Á.; Ojeda, J.C.; Gilpavas, E.; Dobrosz-Gómez, I.; Gómez, M.Á.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)Analyses of temperature, conversion, and their sensitivity with respect to the initial temperature were investigated by parametric sensitivity analysis using a dimensionless batch reactor model for the cyclotrimethylene- triamine synthesis. At first, an expression for its reaction rate was fitted from experimental data available in the literature. Then, a new simple sensitivity-based criterion was used to determine critical operating conditions analyzing temperature sensitivity trajectories. The critical condition of runaway reaction corresponds to a Semenov number (F) equals to 0.684, a heat of reaction parameter (B) equals to 15 and an Arrhenius-type number (?) of 20.Ítem Análisis de la sensibilidad paramétrica y del comportamiento dinámico de la hidrólisis del isocianato de metilo(Centro de Informacion Tecnologica, 2016-01-01) Ojeda, J.C.; GilPavas, E.; Dobrosz-Gómez, I.; Gómez, M.A.; Ojeda, J.C.; GilPavas, E.; Dobrosz-Gómez, I.; Gómez, M.A.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)In this work, parametric sensitivity and dynamic analysis were combined to determine the thermal instability conditions inherent in the methyl isocyanate hydrolysis reaction. This highly exothermic reaction tragically proved to be very sensible to temperature changes in the so-called Bhopal disaster in 1984. A stirred tank reactor in transient state was considered for simulating the reactive system. First, critical operational conditions were defined from the parametric sensitivity analysis. Subsequently, in a rigorous way, the dynamic analysis determined the thermal instability regions, Hopf bifurcations, and the thermal oscillatory behavior of the reactive system. The Matcont® software was used to solve the differential equations set. It was demonstrated that runaway conditions and the periodic solutions of temperature are closely related with the cooling temperature and the dimensionless parameters (f-dimensionless flow and l-heat transfer term) and their critical parameters were obtained: /c=752.39 and fc=1.57.