Examinando por Materia "Elastic Modulus"
Mostrando 1 - 5 de 5
Resultados por página
Opciones de ordenación
Ítem Bone regeneration and docking site healing after bone transport distraction osteogenesis in the canine mandible(W.B. Saunders Ltd, 2012-01-01) Nagashima, L.K.; Rondon-Newby, M.; Zakhary, I.E.; Nagy, W.W.; Zapata, U.; Dechow, P.C.; Opperman, L.A.; Elsalanty, M.E.; Nagashima, L.K.; Rondon-Newby, M.; Zakhary, I.E.; Nagy, W.W.; Zapata, U.; Dechow, P.C.; Opperman, L.A.; Elsalanty, M.E.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaPurpose: Bone transport distraction osteogenesis provides a promising alternative to traditional grafting techniques. However, existing bone transport distraction osteogenesis devices have many limitations. The purpose of this research was to test a new device, the mandibular bone transport reconstruction plate, in an animal model with comparable mandible size to humans and to histologically and mechanically examine the regenerate bone. Materials and Methods: Eleven adult foxhounds were divided into an unreconstructed control group of 5 animals and an experimental group of 6 animals. In each animal, a 34-mm segmental defect was created in the mandible. The defect was reconstructed with a bone transport reconstruction plate. Histologic and biomechanical characteristics of the regenerate and unrepaired defect were analyzed and compared with bone on the contralateral side of the mandible after 4 weeks of consolidation. Results: The reconstructed defect was bridged with new bone, with little bone in the control defect. Regenerate density and microhardness were 22.3% and 42.6%, respectively, lower than the contralateral normal bone. Likewise, the anisotropy of the experimental group was statistically lower than in the contralateral bone. Half the experimental animals showed nonunion at the docking site. Conclusion: The device was very stable and easy to install and activate. After 1 month of consolidation, the defect was bridged with new bone, with evidence of active bone formation. Regenerate bone was less mature than the control bone. Studies are underway to identify when the regenerate properties compare with normal bone and to identify methods to augment bone union at the docking site. © 2012 American Association of Oral and Maxillofacial Surgeons.Ítem Bone regeneration and docking site healing after bone transport distraction osteogenesis in the canine mandible(W.B. Saunders Ltd, 2012-01-01) Nagashima, L.K.; Rondon-Newby, M.; Zakhary, I.E.; Nagy, W.W.; Zapata, U.; Dechow, P.C.; Opperman, L.A.; Elsalanty, M.E.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)Purpose: Bone transport distraction osteogenesis provides a promising alternative to traditional grafting techniques. However, existing bone transport distraction osteogenesis devices have many limitations. The purpose of this research was to test a new device, the mandibular bone transport reconstruction plate, in an animal model with comparable mandible size to humans and to histologically and mechanically examine the regenerate bone. Materials and Methods: Eleven adult foxhounds were divided into an unreconstructed control group of 5 animals and an experimental group of 6 animals. In each animal, a 34-mm segmental defect was created in the mandible. The defect was reconstructed with a bone transport reconstruction plate. Histologic and biomechanical characteristics of the regenerate and unrepaired defect were analyzed and compared with bone on the contralateral side of the mandible after 4 weeks of consolidation. Results: The reconstructed defect was bridged with new bone, with little bone in the control defect. Regenerate density and microhardness were 22.3% and 42.6%, respectively, lower than the contralateral normal bone. Likewise, the anisotropy of the experimental group was statistically lower than in the contralateral bone. Half the experimental animals showed nonunion at the docking site. Conclusion: The device was very stable and easy to install and activate. After 1 month of consolidation, the defect was bridged with new bone, with evidence of active bone formation. Regenerate bone was less mature than the control bone. Studies are underway to identify when the regenerate properties compare with normal bone and to identify methods to augment bone union at the docking site. © 2012 American Association of Oral and Maxillofacial Surgeons.Ítem Design and construction of a transducer for bite force registration.(ELSEVIER SCI LTD, 2009-05-29) Isaza JF; Throckmorton GS; Roldán SI; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)This study describes the development of a system for quantification of human biting forces by (1) determining the mechanical properties of an epoxy resin reinforced with carbon fiber, (2) establishing the transducer's optimal dimensions to accommodate teeth of various widths while minimizing transducer thickness, and (3) determining the optimal location of strain gages using a series of mechanical resistance and finite element (FE) analyses. The optimal strain gage location was defined as the position that produced the least difference in strain pattern when the load was applied by teeth with two different surface areas. The result is a 7.3-mm-thick transducer with a maximum load capacity beyond any expected maximum bite force (1500N). This system includes a graphic interface that easily allows acquisition and registration of bite force by any health-sciences or engineering professional.Ítem Design and construction of a transducer for bite force registration.(ELSEVIER SCI LTD, 2009-05-29) Isaza JF; Throckmorton GS; Roldán SI; Universidad EAFIT. Departamento de Ingeniería de Diseño; Ingeniería de Diseño (GRID)This study describes the development of a system for quantification of human biting forces by (1) determining the mechanical properties of an epoxy resin reinforced with carbon fiber, (2) establishing the transducer's optimal dimensions to accommodate teeth of various widths while minimizing transducer thickness, and (3) determining the optimal location of strain gages using a series of mechanical resistance and finite element (FE) analyses. The optimal strain gage location was defined as the position that produced the least difference in strain pattern when the load was applied by teeth with two different surface areas. The result is a 7.3-mm-thick transducer with a maximum load capacity beyond any expected maximum bite force (1500N). This system includes a graphic interface that easily allows acquisition and registration of bite force by any health-sciences or engineering professional.Ítem The global impact of sutures assessed in a finite element model of a macaque cranium(WILEY-LISS, 2010-09-01) Wang, Qian; Smith, Amanda L.; Strait, David S.; Wright, Barth W.; Richmond, Brian G.; Grosse, Ian R.; Byron, Craig D.; Zapata, Uriel; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)The biomechanical significance of cranial sutures in primates is an open question because their global impact is unclear, and their material properties are difficult to measure. In this study, eight suture-bone functional units representing eight facial sutures were created in a finite element model of a monkey cranium. All the sutures were assumed to have identical isotropic linear elastic material behavior that varied in different modeling experiments, representing either fused or unfused sutures. The values of elastic moduli employed in these trials ranged over several orders of magnitude. Each model was evaluated under incisor, premolar, and molar biting conditions. Results demonstrate that skulls with unfused sutures permitted more deformations and experienced higher total strain energy. However, strain patterns remained relatively unaffected away from the suture sites, and bite reaction force was likewise barely affected. These findings suggest that suture elasticity does not substantially alter load paths through the macaque skull or its underlying rigid body kinematics. An implication is that, for the purposes of finite element analysis, omitting or fusing sutures is a reasonable modeling approximation for skulls with small suture volume fraction if the research objective is to observe general patterns of craniofacial biomechanics under static loading conditions. The manner in which suture morphology and ossification affect the mechanical integrity of skulls and their ontogeny and evolution awaits further investigation, and their viscoelastic properties call for dynamic simulations. © 2010 Wiley-Liss, Inc.