Examinando por Materia "Box-Behnken experimental design"
Mostrando 1 - 8 de 8
Resultados por página
Opciones de ordenación
Ítem Decolorization and mineralization of Diarylide Yellow 12 (PY12) by photo-Fenton process: the Response Surface Methodology as the optimization tool.(IWA PUBLISHING, 2012-01-01) GilPavas, Edison; Dobrosz-Gomez, Izabela; Angel Gomez-Garcia, Miguel; GilPavas, Edison; Dobrosz-Gomez, Izabela; Angel Gomez-Garcia, Miguel; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)The Response Surface Methodology (RSM) was applied as a tool for the optimization of the operational conditions of the photo-degradation of highly concentrated PY12 wastewater, resulting from a textile industry located in the suburbs of Medellin (Colombia). The Box-Behnken experimental Design (BBD) was chosen for the purpose of response optimization. The photo-Fenton process was carried out in a laboratory-scale batch photo-reactor. A multifactorial experimental design was proposed, including the following variables: the initial dyestuff concentration, the H(2)O(2) and the Fe(+2) concentrations, as well as the UV wavelength radiation. The photo-Fenton process performed at the optimized conditions resulted in ca. 100% of dyestuff decolorization, 92% of COD and 82% of TOC degradation. A kinetic study was accomplished, including the identification of some intermediate compounds generated during the oxidation process. The water biodegradability reached a final DBO(5)/DQO = 0.86 value.Ítem Degradación de Colorante Amarillo 12 de Aguas Residuales Industriales utilizando Hierro Cero Valente, Peróxido de Hidrógeno y Radiación Ultravioleta(Centro de Informacion Tecnologica, 2016-01-01) Gilpavas, E.; Medina, J.; Dobrosz-Gómez, I.; Gómez, M.Á.; Gilpavas, E.; Medina, J.; Dobrosz-Gómez, I.; Gómez, M.Á.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)The Fenton heterogeneous process in a fluidized bed reactor using Zero Valent Iron (ZVI), in the metallic state, for the treatment of textile wastewater has been used an analyzed. The aim of this work was to optimize the following operating parameters: initial dye concentration, H2O2 concentration, pH, amount of ZVI, and UV radiation, for the removal of dye and organic matter. At first, a fractional factorial experimental design allows defining the most influential factors. After that, they were optimized using the Response Surface Methodology coupled to the Box-Behnken experimental design. The optimal conditions were found to be as follows: initial dye concentration, 881 mg/L; pH 5; ZVI concentration, 5,31 g/L; H2O2 concentration, 0,86 mL/L. At these conditions, the degradation kinetics was performed, reaching 100% and 80,83% of dye and chemical oxygen demand respectively, in 150 minutes of reaction.Ítem Efficient treatment for textile wastewater through sequential electrocoagulation, electrochemical oxidation and adsorption processes: Optimization and toxicity assessment(Elsevier BV, 2020-01-01) GilPavas E.; Dobrosz-Gómez I.; Gómez-García M.-Á.; GilPavas E.; Dobrosz-Gómez I.; Gómez-García M.-Á.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)In this work, the sequential Electrocoagulation + Electro-oxidation + Activated carbon adsorption (EC + EO + AC) process was studied as an alternative for the treatment of an industrial textile wastewater (TWW) issuing from a manufacturing company located in Medellín (Colombia). The EC's and EO's operational conditions were optimized using a Box-Behnken experimental design, the Response Surface Methodology and a constrained nonlinear optimization algorithm in terms of organic matter degradation efficiency. The best performance for EC (i. e., dye removal = 94%, COD and TOC degradation of 45 and 40%, respectively) was obtained using Fe anode and Boron Doped Diamond (BDD) cathode, with current density, jEC, equals to 5 mA/cm2, pH = 9.3, 60 RPM and 10 min of electrolysis. After EC treatment, the effluent biodegradability (evaluated as the BOD5/COD ratio) increases from 0.14 to 0.23. Regrettably, EC was not effective for the removal of acute toxicity to Artemia salina since the treated effluent remained very toxic (100%). The treatment of EC's effluent by EO enhanced organic pollutant removal. For EC + EO sequential process, EO optimal operational conditions (jEO = 10 mA/cm2, pH = 3, 240 RPM, BDD as anode and Fe as cathode) allowed reduction of 100% of color, 88% of COD and 79% of TOC after 30 min of electrolysis. Moreover, the BOD5/COD ratio increased from 0.23 to 0.58; however, the treated effluent remained very toxic to the Artemia salina. Consequently, an activated carbon adsorption step was included to complete the treatment process. Thus, by coupling the EC + EO + AC process, effluent's acute toxicity decreased completely. From molecular weight distribution analysis, it was concluded that EC + EO was efficient in eliminating low molecular weight (< 5 kDa) compounds. Finally, the operation cost, which includes chemical reagents, electrodes, energy consumption, and sludge disposal, for the EC + EO + AC sequential process was estimated in 3.83 USD /m3. © 2020 Elsevier B.V.Ítem Efficient treatment for textile wastewater through sequential electrocoagulation, electrochemical oxidation and adsorption processes: Optimization and toxicity assessment(Elsevier BV, 2020-01-01) GilPavas E.; Dobrosz-Gómez I.; Gómez-García M.-Á.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Desarrollo y Diseño de ProcesosIn this work, the sequential Electrocoagulation + Electro-oxidation + Activated carbon adsorption (EC + EO + AC) process was studied as an alternative for the treatment of an industrial textile wastewater (TWW) issuing from a manufacturing company located in Medellín (Colombia). The EC's and EO's operational conditions were optimized using a Box-Behnken experimental design, the Response Surface Methodology and a constrained nonlinear optimization algorithm in terms of organic matter degradation efficiency. The best performance for EC (i. e., dye removal = 94%, COD and TOC degradation of 45 and 40%, respectively) was obtained using Fe anode and Boron Doped Diamond (BDD) cathode, with current density, jEC, equals to 5 mA/cm2, pH = 9.3, 60 RPM and 10 min of electrolysis. After EC treatment, the effluent biodegradability (evaluated as the BOD5/COD ratio) increases from 0.14 to 0.23. Regrettably, EC was not effective for the removal of acute toxicity to Artemia salina since the treated effluent remained very toxic (100%). The treatment of EC's effluent by EO enhanced organic pollutant removal. For EC + EO sequential process, EO optimal operational conditions (jEO = 10 mA/cm2, pH = 3, 240 RPM, BDD as anode and Fe as cathode) allowed reduction of 100% of color, 88% of COD and 79% of TOC after 30 min of electrolysis. Moreover, the BOD5/COD ratio increased from 0.23 to 0.58; however, the treated effluent remained very toxic to the Artemia salina. Consequently, an activated carbon adsorption step was included to complete the treatment process. Thus, by coupling the EC + EO + AC process, effluent's acute toxicity decreased completely. From molecular weight distribution analysis, it was concluded that EC + EO was efficient in eliminating low molecular weight (< 5 kDa) compounds. Finally, the operation cost, which includes chemical reagents, electrodes, energy consumption, and sludge disposal, for the EC + EO + AC sequential process was estimated in 3.83 USD /m3. © 2020 Elsevier B.V.Ítem The electrochemical elimination of coliforms from water using BBD/Ti or graphite anodes: A comparative study(International Water Association Publishing, 2018-04-01) Gil Pavas, E.; Arbelaez, Paula Eliana; Medina, J.; Dobrosz-Gómez, I.; Angel Gomez-Garcia, Miguel; Universidad EAFIT. Departamento de Ingeniería de Procesos; Desarrollo y Diseño de ProcesosThe elimination of total and fecal coliforms, from raw surface water, was carried out by electrochemical oxidation using either boron doped diamond (BDD/Ti) or graphite (GP) anodes, in a chloride-free medium. The optimal values of the operation parameters, maximizing the coliform elimination percentage, were determined using statistical experimental design. The current density ( j: 2-20 mA/cm2), the conductivity (s: 500-900 µS/cm) and the anode materials (An) were considered as variables to perform the Box-Behnken experimental design together with the response surface methodology analysis for optimization. The statistical analysis indicated that, in the evaluated range, the disinfection efficiency increased with an increase in j and decreased with an increase in s. The following optimal conditions for the elimination of total and fecal coliforms were found: j: 10 mA/cm2, s: 500 µS/cm and BDD/Ti used as anode material. The BDD/Ti electrode let to achieve complete coliform elimination after ca. 20 min of reaction while the GP one needed ca. 27 min. In water treated with both BDD/Ti and GP anode, after 7 days, any coliforms growth was observed. As a result of the oxidation process, the total organic carbon and nitrite concentration decreased while nitrate concentration increased. © IWA Publishing 2018.Ítem The electrochemical elimination of coliforms from water using BBD/Ti or graphite anodes: A comparative study(International Water Association Publishing, 2018-04-01) Gil Pavas, E.; Arbelaez, Paula Eliana; Medina, J.; Dobrosz-Gómez, I.; Angel Gomez-Garcia, Miguel; Gil Pavas, E.; Arbelaez, Paula Eliana; Medina, J.; Dobrosz-Gómez, I.; Angel Gomez-Garcia, Miguel; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)The elimination of total and fecal coliforms, from raw surface water, was carried out by electrochemical oxidation using either boron doped diamond (BDD/Ti) or graphite (GP) anodes, in a chloride-free medium. The optimal values of the operation parameters, maximizing the coliform elimination percentage, were determined using statistical experimental design. The current density ( j: 2-20 mA/cm2), the conductivity (s: 500-900 µS/cm) and the anode materials (An) were considered as variables to perform the Box-Behnken experimental design together with the response surface methodology analysis for optimization. The statistical analysis indicated that, in the evaluated range, the disinfection efficiency increased with an increase in j and decreased with an increase in s. The following optimal conditions for the elimination of total and fecal coliforms were found: j: 10 mA/cm2, s: 500 µS/cm and BDD/Ti used as anode material. The BDD/Ti electrode let to achieve complete coliform elimination after ca. 20 min of reaction while the GP one needed ca. 27 min. In water treated with both BDD/Ti and GP anode, after 7 days, any coliforms growth was observed. As a result of the oxidation process, the total organic carbon and nitrite concentration decreased while nitrate concentration increased. © IWA Publishing 2018.Ítem Solar and artificial UV inactivation of bacterial microbes by Ca-alginate immobilized TiO2 assisted by H2O2 using fluidized bed photoreactors(SCIENCE & TECHNOLOGY NETWORK INC, 2014-07-01) GilPavas, Edison; Acevedo, Jose; Lopez, Luis F.; Dobrosz-Gomez, Izabela; Angel Gomez-Garcia, Miguel; GilPavas, Edison; Acevedo, Jose; Lopez, Luis F.; Dobrosz-Gomez, Izabela; Angel Gomez-Garcia, Miguel; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)In this work, TiO2 (Degussa, P-25) supported on calcium alginate pearls was evaluated as catalyst for the photocatalytic inhibition of pathogenic microorganisms. Considering that water samples were taken directly from a natural source, a primary treatment (coagulation, sedimentation and filtration) was executed to remove solids and impurities. Photocatalytic experiments were carried out in two types of laboratory scale equipments, one using an annular UV irradiated reactor and the other a solar UV parabolic collector, both operated in the fluidized bed mode. H2O2 was included to the reactive mixture in order to enhance the photodegradation rate. The Response Surface Methodology and the Box-Behnken experimental design techniques were applied as tools for the optimization of the operational conditions of the UV water purification system. Thus, the influence of UV radiation, TiO2 dose and H2O2 concentration on the faecal and total coliform percentage degradation were statistically analysed. The following optimal operational conditions were found: UV radiation = 310 nm, TiO2 dose = 0.2 g/L and H2O2 concentration = 30 mg/L. After water treatment at optimized conditions, total microorganism growing inhibition was observed. Additional experiments allowed proving the reusability of the immobilized catalyst. © 2014 Science & Technology Network, Inc.Ítem Study of APS and conventional sintering parameters for the manufacture of TiO2 targets for PAPVD(IOP PUBLISHING LTD, 2019-01-01) Jaramillo Raquejo D.; Palacio C.C.; Ageorges H.; Jaramillo Raquejo D.; Palacio C.C.; Ageorges H.; Universidad EAFIT. Departamento de Ciencias; Electromagnetismo Aplicado (Gema)In surface science of functional oxides, titanium dioxide (TiO2) is one of the most investigated crystalline systems either in rutile or anatase phases. In this work commercial TiO2 powders are used to study the required process conditions to obtain TiO2 targets by Atmospheric Plasma Spray (APS) and conventional sintering, with suitable physical and chemical properties to be source material for Plasma Assisted Physical Vapor Deposition (PAPVD) for technological and medical applications. Two three factor Box Behnken experimental designs combined with surface modeling were employed to estimate the influence of spraying parameters (gun current, Ar/H2 ratio and standoff distance) and sintering parameters (heating rate, sintering temperature and holding time) within the targets microstructure (cracks and pores in cross section) and phases composition. The microstructure and composition of APS-deposited targets and sintered ones were characterized by Scanning Electron Microscopy (SEM) and X-Ray Diffraction (XRD). The lowest defects percentages of the targets manufactured in this work were 0.41 ± 0.30 % for APS-deposited targets and 0.05 ± 0.04 % for the sintered ones using the optimal parameters suggested by the statistical model, which allowed confirming the advantages of sintering process and limitations of APS in terms of microstructural homogeneity, but also of the use of design of experiments in the modeling of systems of many variables when there is not diagnostic equipment of the processes available. © Published under licence by IOP Publishing Ltd.