Toro, Juan Carlos2016-05-262015http://hdl.handle.net/10784/8536GEA Consulting Engineers, acting as the design engineers, was hired by the owner, East Village 207 Residential LLC2 for energy modeling for compliance with LEED NC V3 -- This report details the results of the energy simulation done with the 100% construction documents -- This report only refers to entities within the LEED3 project boundary -- The project consists of a new eight-story high-end residential condominium building with 81 units, as shown in illustration 1, and approximately 117,905 GSF, equivalent to 10,953.73 m2, is located at 211 E 13th Street in New York, NY -- The residential portion of the building will function 24-7 -- The design goal is to utilize energy efficient measures to reduce electrical energy use and aims to achieve LEED certification -- LEED EA Credit 14 requires a building to demonstrate a percentage improvement in the proposed building performance compared with the baseline building -- The Credit rewards 1 point for achieving 12% reduction in energy costs -- Additionally, the Credit rewards another point for each subsequent reduction of 2% in the building’s energy costspaIluminación inteligenteIluminación industrialIluminación LEDLED (Diodo emisor de luz)Energy efficient measures to reduce electrical energy use in commercial buildings in New York Cityinfo:eu-repo/semantics/bachelorThesisinfo:eu-repo/semantics/openAccessEDIFICIOS - ABASTECIMIENTO DE ENERGÍACONSUMO DE ENERGÍA ELÉCTRICACONSERVACIÓN DE LA ENERGÍA ELÉCTRICAILUMINACIÓN DE INTERIORESRENDIMIENTO ENERGÉTICOBuildings - power supplyElectric power consumptionElectric power - conservationInterior lightingEnergy efficiencyAcceso abierto2016-05-26Flórez Toro, Catalina