Optimal power flow using the gradient method to reduce electrical losses in power systems

dc.citation.epage85
dc.citation.issue7
dc.citation.journalAbbreviatedTitleing.cienc.eng
dc.citation.journalTitleIngeniería y Cienciaeng
dc.citation.spage71
dc.citation.volume4
dc.contributor.affiliationUniversidad de Antioquiaspa
dc.contributor.affiliationUniversidade Estadual Paulistaspa
dc.contributor.authorLópez Lezama, Jesús Maríaspa
dc.contributor.authorGallego Pareja, Luis Alfonsospa
dc.coverage.spatialMedellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degreeseng
dc.date2008-06-10
dc.date.accessioned2019-11-22T19:10:48Z
dc.date.available2019-11-22T19:10:48Z
dc.date.issued2008-06-10
dc.descriptionThis article presents an optimal power flow model by the gradient method for reducing losses in power systems. The algorithm allows a set of control variables to be adjusted in order to obtain an operating point that minimizes power losses. The method is based on the solution of the power flow by the Newton method. The limits of the independent variables are managed through penalty functions. The performance of the algorithm is evaluated using two different methods to calculate the size of the step along the feasible direction: a constant step and a variable step using the debolabola adjustment method.eng
dc.descriptionEn este artículo se presenta un modelo de flujo de potencia óptimo por elmétodo del gradiente para la reducción de pérdidas en sistemas de potencia.El algoritmo permite ajustar un conjunto de variables de control con el finde obtener un punto de operación que minimice las pérdidas de potencia activa.El método se basa en la solución del flujo de potencia por el método deNewton. Los límites de las variables independientes son manejados mediantefunciones de penalidad. El desempeño del algoritmo es evaluado usando dosmétodos diferentes para calcular el tamaño del paso a lo largo de la direcciónfactible: un paso constante y un paso variable usando el método de ajuste depar´abola.spa
dc.formatapplication/pdf
dc.identifier.issn2256-4314
dc.identifier.issn1794-9165
dc.identifier.urihttp://hdl.handle.net/10784/14528
dc.language.isospaspa
dc.publisherUniversidad EAFITspa
dc.relation.isversionofhttp://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/230
dc.relation.urihttp://publicaciones.eafit.edu.co/index.php/ingciencia/article/view/230
dc.rightsCopyright (c) 2008 Jesús María López Lezama, Luis Alfonso Gallego Parejaeng
dc.rights.accessrightsinfo:eu-repo/semantics/openAccesseng
dc.rights.localAcceso abiertospa
dc.sourceinstname:Universidad EAFIT
dc.sourcereponame:Repositorio Institucional Universidad EAFIT
dc.sourceIngeniería y Ciencia; Vol 4, No 7 (2008)spa
dc.subject.keywordOptimal Power Floweng
dc.subject.keywordReduction Of Active Power Losseseng
dc.subject.keywordOptimization In Power Systemseng
dc.subject.keywordFlujo De Potencia Óptimospa
dc.subject.keywordReducción De Pérdidas Activas De Potenciaspa
dc.subject.keywordOptimización En Sistemas De Potenciaspa
dc.titleOptimal power flow using the gradient method to reduce electrical losses in power systemseng
dc.titleFlujo de potencia óptimo usando el método del gradiente para reducción de pérdidas en sistemas de potenciaspa
dc.typearticleeng
dc.typeinfo:eu-repo/semantics/articleeng
dc.typepublishedVersioneng
dc.typeinfo:eu-repo/semantics/publishedVersioneng
dc.type.localArtículospa

Archivos

Bloque original
Mostrando 1 - 2 de 2