Implementation of a preamplifier-amplifier system for radiation detectors used in Mössbauer spectroscopy
dc.citation.journalTitle | Hyperfine Interactions | |
dc.contributor.author | Velasquez, A. A. | |
dc.contributor.author | Arroyave, M. | |
dc.contributor.department | Universidad EAFIT. Departamento de Ciencias Básicas | |
dc.contributor.researchgroup | Electromagnetismo Aplicado (Gema) | spa |
dc.date.accessioned | 2021-03-23T21:38:58Z | |
dc.date.available | 2021-03-23T21:38:58Z | |
dc.date.issued | 2014-01-01 | |
dc.description.abstract | We report the assembly and testing of a preamplification and amplification system for pulses produced by gaseous radiation detectors commonly used in Mössbauer spectroscopy. The system is composed by a pair of commercial integrated circuits A203 and A206, which operate as charge sensitive preamplifier-shaping amplifier and linear amplifier-low level discriminator, respectively. The integrated circuits were interconnected in the unipolar output mode and placed inside a metallic shielding, which prevents noise amplification for a suitable signal-noise ratio. The system was tested by irradiating a proportional counter LND-45431 with characteristic X rays of 6.3 keV and gamma rays of 14.4 keV emitted by a Mössbauer radioactive source of 57Co (Rh). Unipolar pulses with Gaussian profile were obtained at the output of the linear amplifier, whose amplitudes were close to 0.4 V for 6.3 keV X rays and 1.4 V for 14.4 keV gamma rays. Pulse height spectra showed that the system allows a satisfactory identification of the X-rays and gamma rays emitted by the 57Co source, giving the possibility to make a good selection of the 14.4 keV peak for having a suitable signal-noise ratio in the Mössbauer spectra. Absorption percentages of 14 % were found by taking the Mössbauer spectra of a natural iron absorber. The assembly and tests of the system are presented through this paper. © 2013 Springer Science+Business Media Dordrecht. | eng |
dc.identifier | https://eafit.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=1270 | |
dc.identifier.doi | 10.1007/s10751-013-0818-5 | |
dc.identifier.issn | 03043843 | spa |
dc.identifier.issn | 15729540 | spa |
dc.identifier.other | WOS;000328068400009 | |
dc.identifier.other | SCOPUS;2-s2.0-84889254561 | |
dc.identifier.uri | http://hdl.handle.net/10784/27111 | |
dc.language.iso | eng | eng |
dc.publisher | SPRINGER | |
dc.relation.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84889254561&doi=10.1007%2fs10751-013-0818-5&partnerID=40&md5=72a114c2e8f15a28953aeb003198bd5d | |
dc.rights | https://v2.sherpa.ac.uk/id/publication/issn/0304-3843 | |
dc.source | Hyperfine Interactions | |
dc.subject.keyword | Mössbauer spectroscopy | eng |
dc.subject.keyword | Preamplifier and amplifier system | eng |
dc.subject.keyword | Radiation detectors | eng |
dc.title | Implementation of a preamplifier-amplifier system for radiation detectors used in Mössbauer spectroscopy | eng |
dc.type | article | eng |
dc.type | info:eu-repo/semantics/article | eng |
dc.type | info:eu-repo/semantics/publishedVersion | eng |
dc.type | publishedVersion | eng |
dc.type.local | Artículo | spa |
Archivos
Bloque original
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- s10751-013-0818-5.pdf
- Tamaño:
- 558.38 KB
- Formato:
- Adobe Portable Document Format
- Descripción: