dc.description.abstractThis paper describes the methodology used to design a custom-made cranial implant for a 26 year-old patient, who suffered a lesion in the left frontoparietal region of the skull caused by a fibrous dysplasia. The design of the implant was carried out from the 3D reconstruction of the skull of the patient, obtained by a CT- Scan, using Rapid Form 2006. Once the preliminary design was obtained, 3D models of the injured region of the skull and implant were fabricated in a Rapid Prototyping (RP) machine using the Fused Deposition Modeling Technology (FDM) with the purpose of making a functional and dimensional validation of the implant. Subsequently, the implant was fabricated in titanium alloy (Ti6Al4V). With the methodology, the prosthesis was successfully implanted. The surgical time decreased by 50%, compared with the same type of surgery in which standard commercial implants and titanium meshes are used; due, principally, to the need of implementing trial and error procedures, which intend to achieve a good fit of the implant increasing the risk of the patient. Finally, the aesthetic appearance of the patient was recovered, allowing the patient to safely perform daily activities. © 2013 Springer.eng
dc.identifierhttps://eafit.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=2389
dc.identifier.doi10.1007/978-3-642-21198-0_307
dc.identifier.issn16800737
dc.identifier.otherSCOPUS;2-s2.0-84875264977
dc.identifier.urihttp://hdl.handle.net/10784/28861
dc.language.isoengeng
dc.publisherSPRINGER
dc.relation.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84875264977&doi=10.1007%2f978-3-642-21198-0_307&partnerID=40&md5=cb475226fabebe3dbda232722cb87ada
dc.rightshttps://v2.sherpa.ac.uk/id/publication/issn/1680-0737
dc.sourceIfmbe Proceedings
dc.subject.keyword3D reconstructioneng
dc.subject.keywordCranial implantseng
dc.subject.keywordDaily activityeng
dc.subject.keywordFibrous dysplasiaeng
dc.subject.keywordFused deposition modelingeng
dc.subject.keywordPreliminary designeng
dc.subject.keywordTitanium mesheseng
dc.subject.keywordTrial-and-error procedureseng
dc.subject.keywordBiomedical engineeringeng
dc.subject.keywordComputerized tomographyeng
dc.subject.keywordDesigneng
dc.subject.keywordRapid prototypingeng
dc.subject.keywordTransplantation (surgical)eng
dc.subject.keywordImplants (surgical)eng
dc.titleDiseño y manufactura de un implante personalizado de cráneospa
dc.typeinfo:eu-repo/semantics/conferencePapereng
dc.typeconferencePapereng
dc.typeinfo:eu-repo/semantics/publishedVersioneng
dc.typepublishedVersioneng
dc.type.localDocumento de conferenciaspa

Archivos