Examinando por Materia "electrode"
Mostrando 1 - 5 de 5
Resultados por página
Opciones de ordenación
Ítem The Box-Benkhen experimental design for the optimization of the electrocatalytic treatment of wastewaters with high concentrations of phenol and organic matter.(IWA PUBLISHING, 2009-01-01) GilPavas, Edison; Betancourt, Alejandra; Angulo, Monica; Dobrosz-Gomez, Izabela; Angel Gomez-Garcia, Miguel; GilPavas, Edison; Betancourt, Alejandra; Angulo, Monica; Dobrosz-Gomez, Izabela; Angel Gomez-Garcia, Miguel; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)In this work, the Box-Benkhen experimental Design (BBD) was applied for the optimization of the parameters of the electrocatalytic degradation of wastewaters resulting from a phenolic resins industry placed in the suburbs of Medellin (Colombia). The direct and the oxidant assisted electro-oxidation experiments were carried out in a laboratory scale batch cell reactor, with monopolar configuration, and electrodes made of graphite (anode) and titanium (cathode). A multifactorial experimental design was proposed, including the following experimental variables: initial phenol concentration, conductivity, and pH. The direct electro-oxidation process allowed to reach ca. 88% of phenol degradation, 38% of mineralization (TOC), 52% of Chemical Oxygen Demand (COD) degradation, and an increase in water biodegradability of 13%. The synergetic effect of the electro-oxidation process and the respective oxidant agent (Fenton reactant, potassium permanganate, or sodium persulfate) let to a significant increase in the rate of the degradation process. At the optimized variables values, it was possible to reach ca. 99% of phenol degradation, 80% of TOC and 88% of COD degradation. A kinetic study was accomplished, which included the identification of the intermediate compounds generated during the oxidation process.Ítem The electrochemical elimination of coliforms from water using BBD/Ti or graphite anodes: A comparative study(International Water Association Publishing, 2018-04-01) Gil Pavas, E.; Arbelaez, Paula Eliana; Medina, J.; Dobrosz-Gómez, I.; Angel Gomez-Garcia, Miguel; Universidad EAFIT. Departamento de Ingeniería de Procesos; Desarrollo y Diseño de ProcesosThe elimination of total and fecal coliforms, from raw surface water, was carried out by electrochemical oxidation using either boron doped diamond (BDD/Ti) or graphite (GP) anodes, in a chloride-free medium. The optimal values of the operation parameters, maximizing the coliform elimination percentage, were determined using statistical experimental design. The current density ( j: 2-20 mA/cm2), the conductivity (s: 500-900 µS/cm) and the anode materials (An) were considered as variables to perform the Box-Behnken experimental design together with the response surface methodology analysis for optimization. The statistical analysis indicated that, in the evaluated range, the disinfection efficiency increased with an increase in j and decreased with an increase in s. The following optimal conditions for the elimination of total and fecal coliforms were found: j: 10 mA/cm2, s: 500 µS/cm and BDD/Ti used as anode material. The BDD/Ti electrode let to achieve complete coliform elimination after ca. 20 min of reaction while the GP one needed ca. 27 min. In water treated with both BDD/Ti and GP anode, after 7 days, any coliforms growth was observed. As a result of the oxidation process, the total organic carbon and nitrite concentration decreased while nitrate concentration increased. © IWA Publishing 2018.Ítem The electrochemical elimination of coliforms from water using BBD/Ti or graphite anodes: A comparative study(International Water Association Publishing, 2018-04-01) Gil Pavas, E.; Arbelaez, Paula Eliana; Medina, J.; Dobrosz-Gómez, I.; Angel Gomez-Garcia, Miguel; Gil Pavas, E.; Arbelaez, Paula Eliana; Medina, J.; Dobrosz-Gómez, I.; Angel Gomez-Garcia, Miguel; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)The elimination of total and fecal coliforms, from raw surface water, was carried out by electrochemical oxidation using either boron doped diamond (BDD/Ti) or graphite (GP) anodes, in a chloride-free medium. The optimal values of the operation parameters, maximizing the coliform elimination percentage, were determined using statistical experimental design. The current density ( j: 2-20 mA/cm2), the conductivity (s: 500-900 µS/cm) and the anode materials (An) were considered as variables to perform the Box-Behnken experimental design together with the response surface methodology analysis for optimization. The statistical analysis indicated that, in the evaluated range, the disinfection efficiency increased with an increase in j and decreased with an increase in s. The following optimal conditions for the elimination of total and fecal coliforms were found: j: 10 mA/cm2, s: 500 µS/cm and BDD/Ti used as anode material. The BDD/Ti electrode let to achieve complete coliform elimination after ca. 20 min of reaction while the GP one needed ca. 27 min. In water treated with both BDD/Ti and GP anode, after 7 days, any coliforms growth was observed. As a result of the oxidation process, the total organic carbon and nitrite concentration decreased while nitrate concentration increased. © IWA Publishing 2018.Ítem The removal of the trivalent chromium from the leather tannery wastewater: the optimisation of the electro-coagulation process parameters.(IWA PUBLISHING, 2011-02-01) GilPavas, E.; Dobrosz-Gomez, I.; Gomez-Garcia, M. A.; GilPavas, E.; Dobrosz-Gomez, I.; Gomez-Garcia, M. A.; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)The capacity of the electro-coagulation (EC) process for the treatment of the wastewater containing Cr3+, resulting from a leather tannery industry placed in Medellin (Colombia), was evaluated. In order to assess the effect of some parameters, such as: the electrode type (Al and/or Fe), the distance between electrodes, the current density, the stirring velocity, and the initial Cr3+ concentration on its efficiency of removal (%RCr+3), a multifactorial experimental design was used. The %RCr3+ was defined as the response variable for the statistical analysis. In order to optimise the operational values for the chosen parameters, the response surface method (RSM) was applied. Additionally, the Biological Oxygen Demand (BOD5), the Chemical Oxygen Demand (COD), and the Total Organic Carbon (TOC) were monitored during the EC process. The electrodes made of aluminium appeared to be the most effective in the chromium removal from the wastewater under study. At pH equal to 4.52 and at 28 degrees C, the optimal conditions of Cr3+ removal using the EC process were found, as follows: the initial Cr3+ concentration=3,596 mg/L, the electrode gap=0.5 cm, the stirring velocity=382.3 rpm, and the current density=57.87 mA/cm2. At those conditions, it was possible to reach 99.76% of Cr3+ removal, and 64% and 61% of mineralisation (TOC) and COD removal, respectively. A kinetic analysis was performed in order to verify the response capacity of the EC process at optimised parameter values.Ítem Treatment of automotive industry oily wastewater by electrocoagulation: statistical optimization of the operational parameters.(IWA PUBLISHING, 2009-11-01) GilPavas, Edison; Molina-Tirado, Kevin; Angel Gomez-Garcia, Miguel; GilPavas, Edison; Molina-Tirado, Kevin; Angel Gomez-Garcia, Miguel; Universidad EAFIT. Departamento de Ingeniería de Procesos; Procesos Ambientales (GIPAB)An electrocoagulation process was used for the treatment of oily wastewater generated from an automotive industry in Medellin (Colombia). An electrochemical cell consisting of four parallel electrodes (Fe and Al) in bipolar configuration was implemented. A multifactorial experimental design was used for evaluating the influence of several parameters including: type and arrangement of electrodes, pH, and current density. Oil and grease removal was defined as the response variable for the statistical analysis. Additionally, the BOD(5), COD, and TOC were monitored during the treatment process. According to the results, at the optimum parameter values (current density = 4.3 mA/cm(2), distance between electrodes = 1.5 cm, Fe as anode, and pH = 12) it was possible to reach a c.a. 95% oils removal, COD and mineralization of 87.4% and 70.6%, respectively. A final biodegradability (BOD(5)/COD) of 0.54 was reached.