Examinando por Materia "computer assisted tomography"
Mostrando 1 - 2 de 2
Resultados por página
Opciones de ordenación
Ítem Creation of a three-dimensional model of the mandible and the TMJ in vivo by means of the finite element method.(Quintessenz Verlags GmbH, 2002-04-01) Castaño MC; Zapata U; Pedroza A; Jaramillo JD; Roldán S; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)The aim of this study was to develop a three-dimensional finite element model of the mandible, including its TMJ. The model consisted of 7942 nodes and 41,010 elements, which were obtained from a convergence test, done to minimize the result error. It included cancellous and cortical bone, periodontal ligament, masticatory muscles (masseters, temporalis, lateral and internal pterygoids), teeth and the articular disk. All characteristics such as dental, mandibular, and muscle geometry were obtained from a computerized tomography (CT) of a living person. CT sections were scanned and digitized with a CAD software program. After images were adequately assembled, a vertical tracing was done which allowed the definition of a three-dimensional mesh. Modeling of teeth was carried out independently and the periodontal ligament was later included, limiting the alveolar area. Muscles were modeled based on flat-scale photographs and total muscle force was distributed in multiple vectors. The articular disk was generated having 2 mm of thickness with the combination of spring-type (axial stiffness) and gap-type (contact) elements. The model was then analyzed with finite element method (FEM) software where a mesh was generated and values for Poisson's ratio, elasticity, and shear modulus were assigned. These were orthotropic for cancellous and cortical bone, and isotropic for dentin, periodontal ligament, articular disk, and temporal bone. The boundary conditions were defined restricting the nodes on the periphery of the temporal bone. It was therefore possible to generate a three-dimensional finite element model based on information obtained in vivo.Ítem Ejecución de un sistema piloto de tele-radiología en Medellín, Colombia(Corporacion Editora Medica del Valle, 2006-01-01) García, A.; Isaza, J.F.; Zapata, U.; Roldán, S.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)Objective: To implement a teleradiology pilot system in Medellín city using software for remote access, this allows the communication and interpretation of biomedical images at distance. Materials and methods: Images from different magnetic resonance and computed tomography studies stored in DICOM format were used. Data were transmitted in a point-to-point network using an integrated services digital network (ISDN) line between two radiological diagnostic centers. The system was developed under PC Intel's ×86 architecture, with Windows® 2000 as the operating system. Results: In order to read and visualize images stored in DICOM format, a Java application with functions that allow their manipulation and the option to export them to other formats such as JPEG, TIFF and BMP was developed. Conclusion: The system allows a clinically reliable diagnostic and remote interpretation for modalities such as computed tomography (CT) and magnetic resonance (MR) images, with acceptable response times. © 2006 Corporación Editora Médica del Valle.