Examinando por Materia "animal experiment"
Mostrando 1 - 13 de 13
Resultados por página
Opciones de ordenación
Ítem Architecture and microstructure of cortical bone in reconstructed canine mandibles after bone transport distraction osteogenesis(SPRINGER, 2011-11-01) Zapata, Uriel; Halvachs, Emily K.; Dechow, Paul C.; Elsalanty, Mohammed E.; Opperman, Lynne A.; Zapata, Uriel; Halvachs, Emily K.; Dechow, Paul C.; Elsalanty, Mohammed E.; Opperman, Lynne A.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaReconstruction of the canine mandible using bone transport distraction osteogenesis has been shown to be a suitable method for correcting segmental bone defects produced by cancer, gunshots, and trauma. Although the mechanical quality of the new regenerate cortical bone seems to be related to the mineralization process, several questions regarding the microstructural patterns of the new bony tissue remain unanswered. The purpose of this study was to quantify any microstructural differences that may exist between the regenerate and control cortical bone. Five adult American foxhound dogs underwent unilateral bone transport distraction of the mandible to repair bone defects of 30-35 mm. Animals were killed 12 weeks after the beginning of the consolidation period. Fourteen cylindrical cortical samples were extracted from the superior, medial, and inferior aspects of the lingual and buccal plates of the reconstructed aspect of the mandible, and 21 specimens were collected similarly from the contralateral aspect of the mandible. Specimens were evaluated using histomorphometric and micro-computed tomographic techniques to compare their microstructure. Except for differences in haversian canal area, histomorphometric analyses suggested no statistical differences in microstructure between regenerate and control cortical bone. Morphological evaluation suggested a consistent level of anisotropy, possibly related to the distraction vector. After 12 weeks' consolidation, bone created during bone transport distraction osteogenesis was comparable to native bone in microstructure, architecture, and mechanical properties. It is proposed that, after enough time, the properties of the regenerate bone will be identical to that of native bone. © Springer Science+Business Media, LLC 2010.Ítem Architecture and microstructure of cortical bone in reconstructed canine mandibles after bone transport distraction osteogenesis(SPRINGER, 2011-11-01) Zapata, Uriel; Halvachs, Emily K.; Dechow, Paul C.; Elsalanty, Mohammed E.; Opperman, Lynne A.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)Reconstruction of the canine mandible using bone transport distraction osteogenesis has been shown to be a suitable method for correcting segmental bone defects produced by cancer, gunshots, and trauma. Although the mechanical quality of the new regenerate cortical bone seems to be related to the mineralization process, several questions regarding the microstructural patterns of the new bony tissue remain unanswered. The purpose of this study was to quantify any microstructural differences that may exist between the regenerate and control cortical bone. Five adult American foxhound dogs underwent unilateral bone transport distraction of the mandible to repair bone defects of 30-35 mm. Animals were killed 12 weeks after the beginning of the consolidation period. Fourteen cylindrical cortical samples were extracted from the superior, medial, and inferior aspects of the lingual and buccal plates of the reconstructed aspect of the mandible, and 21 specimens were collected similarly from the contralateral aspect of the mandible. Specimens were evaluated using histomorphometric and micro-computed tomographic techniques to compare their microstructure. Except for differences in haversian canal area, histomorphometric analyses suggested no statistical differences in microstructure between regenerate and control cortical bone. Morphological evaluation suggested a consistent level of anisotropy, possibly related to the distraction vector. After 12 weeks' consolidation, bone created during bone transport distraction osteogenesis was comparable to native bone in microstructure, architecture, and mechanical properties. It is proposed that, after enough time, the properties of the regenerate bone will be identical to that of native bone. © Springer Science+Business Media, LLC 2010.Ítem Biomechanics of the canine mandible during bone transport distraction osteogenesis(ASME, 2014-11-01) Zapata, Uriel; Dechow, Paul C.; Watanabe, Ikuya; Elsalanty, Mohammed E.; Opperman, Lynne A.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)This study compared biomechanical patterns between finite element models (FEMs) and a fresh dog mandible tested under molar and incisal physiological loads in order to clarify the effect of the bone transport distraction osteogenesis (BTDO) surgical process. Three FEMs of dog mandibles were built in order to evaluate the effects of BTDO. The first model evaluated the mandibular response under two physiological loads resembling bite processes. In the second model, a 5.0 cm bone defect was bridged with a bone transport reconstruction plate (BTRP). In the third model, new regenerated bony tissue was incorporated within the defect to mimic the surgical process without the presence of the device. Complementarily, a mandible of a male American foxhound dog was mechanically tested in the laboratory both in the presence and absence of a BTRP, and mechanical responses were measured by attaching rosettes to the bone surface of the mandible to validate the FEM predictions. The relationship between real and predicted values indicates that the stress patterns calculated using FEM are a valid predictor of the biomechanics of the BTDO procedures. The present study provides an interesting correlation between the stiffness of the device and the biomechanical response of the mandible affected for bone transport. Copyright © 2014 by ASME.Ítem Biomechanics of the canine mandible during bone transport distraction osteogenesis(ASME, 2014-11-01) Zapata, Uriel; Dechow, Paul C.; Watanabe, Ikuya; Elsalanty, Mohammed E.; Opperman, Lynne A.; Zapata, Uriel; Dechow, Paul C.; Watanabe, Ikuya; Elsalanty, Mohammed E.; Opperman, Lynne A.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaThis study compared biomechanical patterns between finite element models (FEMs) and a fresh dog mandible tested under molar and incisal physiological loads in order to clarify the effect of the bone transport distraction osteogenesis (BTDO) surgical process. Three FEMs of dog mandibles were built in order to evaluate the effects of BTDO. The first model evaluated the mandibular response under two physiological loads resembling bite processes. In the second model, a 5.0 cm bone defect was bridged with a bone transport reconstruction plate (BTRP). In the third model, new regenerated bony tissue was incorporated within the defect to mimic the surgical process without the presence of the device. Complementarily, a mandible of a male American foxhound dog was mechanically tested in the laboratory both in the presence and absence of a BTRP, and mechanical responses were measured by attaching rosettes to the bone surface of the mandible to validate the FEM predictions. The relationship between real and predicted values indicates that the stress patterns calculated using FEM are a valid predictor of the biomechanics of the BTDO procedures. The present study provides an interesting correlation between the stiffness of the device and the biomechanical response of the mandible affected for bone transport. Copyright © 2014 by ASME.Ítem Bone regeneration and docking site healing after bone transport distraction osteogenesis in the canine mandible(W.B. Saunders Ltd, 2012-01-01) Nagashima, L.K.; Rondon-Newby, M.; Zakhary, I.E.; Nagy, W.W.; Zapata, U.; Dechow, P.C.; Opperman, L.A.; Elsalanty, M.E.; Nagashima, L.K.; Rondon-Newby, M.; Zakhary, I.E.; Nagy, W.W.; Zapata, U.; Dechow, P.C.; Opperman, L.A.; Elsalanty, M.E.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaPurpose: Bone transport distraction osteogenesis provides a promising alternative to traditional grafting techniques. However, existing bone transport distraction osteogenesis devices have many limitations. The purpose of this research was to test a new device, the mandibular bone transport reconstruction plate, in an animal model with comparable mandible size to humans and to histologically and mechanically examine the regenerate bone. Materials and Methods: Eleven adult foxhounds were divided into an unreconstructed control group of 5 animals and an experimental group of 6 animals. In each animal, a 34-mm segmental defect was created in the mandible. The defect was reconstructed with a bone transport reconstruction plate. Histologic and biomechanical characteristics of the regenerate and unrepaired defect were analyzed and compared with bone on the contralateral side of the mandible after 4 weeks of consolidation. Results: The reconstructed defect was bridged with new bone, with little bone in the control defect. Regenerate density and microhardness were 22.3% and 42.6%, respectively, lower than the contralateral normal bone. Likewise, the anisotropy of the experimental group was statistically lower than in the contralateral bone. Half the experimental animals showed nonunion at the docking site. Conclusion: The device was very stable and easy to install and activate. After 1 month of consolidation, the defect was bridged with new bone, with evidence of active bone formation. Regenerate bone was less mature than the control bone. Studies are underway to identify when the regenerate properties compare with normal bone and to identify methods to augment bone union at the docking site. © 2012 American Association of Oral and Maxillofacial Surgeons.Ítem Bone regeneration and docking site healing after bone transport distraction osteogenesis in the canine mandible(W.B. Saunders Ltd, 2012-01-01) Nagashima, L.K.; Rondon-Newby, M.; Zakhary, I.E.; Nagy, W.W.; Zapata, U.; Dechow, P.C.; Opperman, L.A.; Elsalanty, M.E.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)Purpose: Bone transport distraction osteogenesis provides a promising alternative to traditional grafting techniques. However, existing bone transport distraction osteogenesis devices have many limitations. The purpose of this research was to test a new device, the mandibular bone transport reconstruction plate, in an animal model with comparable mandible size to humans and to histologically and mechanically examine the regenerate bone. Materials and Methods: Eleven adult foxhounds were divided into an unreconstructed control group of 5 animals and an experimental group of 6 animals. In each animal, a 34-mm segmental defect was created in the mandible. The defect was reconstructed with a bone transport reconstruction plate. Histologic and biomechanical characteristics of the regenerate and unrepaired defect were analyzed and compared with bone on the contralateral side of the mandible after 4 weeks of consolidation. Results: The reconstructed defect was bridged with new bone, with little bone in the control defect. Regenerate density and microhardness were 22.3% and 42.6%, respectively, lower than the contralateral normal bone. Likewise, the anisotropy of the experimental group was statistically lower than in the contralateral bone. Half the experimental animals showed nonunion at the docking site. Conclusion: The device was very stable and easy to install and activate. After 1 month of consolidation, the defect was bridged with new bone, with evidence of active bone formation. Regenerate bone was less mature than the control bone. Studies are underway to identify when the regenerate properties compare with normal bone and to identify methods to augment bone union at the docking site. © 2012 American Association of Oral and Maxillofacial Surgeons.Ítem Material properties of mandibular cortical bone in the American alligator, Alligator mississippiensis(ELSEVIER SCIENCE INC, 2010-03-01) Zapata, Uriel; Metzger, Keith; Wang, Qian; Elsey, Ruth M.; Ross, Callum F.; Dechow, Paul C.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)This study reports the elastic material properties of cortical bone in the mandible of juvenile Alligator mississippiensis obtained by using an ultrasonic wave technique. The elastic modulus, the shear modulus, and Poisson's ratio were measured on 42 cylindrical Alligator bone specimens obtained from the lingual and facial surfaces of 4 fresh Alligator mandibles. The data suggest that the elastic properties of alligator mandibular cortical bone are similar to those found in mammals and are orthotropic. The properties most resemble those found in the cortex of mammalian postcranial long bones where the bone is most stiff in one direction and much less stiff in the two remaining orthogonal directions. This is different from cortical bone found in the mandibles of humans and some monkeys, where the bone has greatest stiffness in one direction, much less stiffness in another direction, and an intermediate amount in the third orthogonal direction. This difference suggests a relationship between levels of orthotropy and bending stress. The comparability of these elastic moduli to those of other vertebrates suggest that the high bone strain magnitudes recorded from the alligator mandible in vivo are not attributable to a lower stiffness of alligator mandibular bone. © 2009 Elsevier Inc.Ítem Material properties of the skull layers of the primate parietal bone: A single-subject study(Public Library of Science, 2020-01-01) Zapata, U.; Wang, Q.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)The outer cortical table of the parietal bone has been commonly used as a calvarial bone graft site for the craniofacial reconstruction. However, little is known about how removing the outer table may affect the function and structure of the inner table, and how the knowledge of the biomechanics and material properties of cortical bones will help the calvarial graft to better integrate into the biological and mechanical functions of its surrounding native tissues. In this study, it was hypothesized that there were significant differences in both density and material properties between inner and outer cortical plates in cranial bones. Twelve cylindrical specimens, including inner-outer layers, of cortical parietal bone of a female baboon were collected. Cortical thicknesses and densities were measured, and elastic properties were assessed using an ultrasonic technique. Results demonstrated remarkable difference in both thickness (t = 8.248, p .0.05) and density (t = 4.926, p.0.05) between inner and outer cortical paired samples. Orthotropic characteristics of the cortical plates were detected as well, these findings suggest that there are differences in biomechanical properties between two surfaces of cranial bones at both tissue and organ levels. How these differences are linked to the stress environments of the inner and outer cranial cortical layers awaits further studies. Further study will greatly enhance our ability to address questions derived from both morphological and craniofacial medicine fields about the development and biomechanics of craniofacial skeletons. © 2020 Zapata, Wang.Ítem Material properties of the skull layers of the primate parietal bone: A single-subject study(Public Library of Science, 2020-01-01) Zapata, U.; Wang, Q.; Zapata, U.; Wang, Q.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaThe outer cortical table of the parietal bone has been commonly used as a calvarial bone graft site for the craniofacial reconstruction. However, little is known about how removing the outer table may affect the function and structure of the inner table, and how the knowledge of the biomechanics and material properties of cortical bones will help the calvarial graft to better integrate into the biological and mechanical functions of its surrounding native tissues. In this study, it was hypothesized that there were significant differences in both density and material properties between inner and outer cortical plates in cranial bones. Twelve cylindrical specimens, including inner-outer layers, of cortical parietal bone of a female baboon were collected. Cortical thicknesses and densities were measured, and elastic properties were assessed using an ultrasonic technique. Results demonstrated remarkable difference in both thickness (t = 8.248, p .0.05) and density (t = 4.926, p.0.05) between inner and outer cortical paired samples. Orthotropic characteristics of the cortical plates were detected as well, these findings suggest that there are differences in biomechanical properties between two surfaces of cranial bones at both tissue and organ levels. How these differences are linked to the stress environments of the inner and outer cranial cortical layers awaits further studies. Further study will greatly enhance our ability to address questions derived from both morphological and craniofacial medicine fields about the development and biomechanics of craniofacial skeletons. © 2020 Zapata, Wang.Ítem Paracoccidioides spp. catalases and their role in antioxidant defense against host defense responses(Elsevier, 2017-03-01) Tamayo, D.; Muñoz, J.F.; Almeida, A.J.; Puerta, J.D.; Restrepo, Á.; Cuomo, C.A.; McEwen, J.G.; Hernández, O.; Universidad EAFIT. Departamento de Ciencias; Ciencias Biológicas y Bioprocesos (CIBIOP)Dimorphic human pathogenic fungi interact with host effector cells resisting their microbicidal mechanisms. Yeast cells are able of surviving within the tough environment of the phagolysosome by expressing an antioxidant defense system that provides protection against host-derived reactive oxygen species (ROS). This includes the production of catalases (CATs). Here we identified and analyzed the role of CAT isoforms in Paracoccidioides, the etiological agent of paracoccidioidomycosis. Firstly, we found that one of these isoforms was absent in the closely related dimorphic pathogen Coccidioides and dermatophytes, but all of them were conserved in Paracoccidioides, Histoplasma and Blastomyces species. We probed the contribution of CATs in Paracoccidioides by determining the gene expression levels of each isoform through quantitative RT-qPCR, in both the yeast and mycelia phases, and during the morphological switch (transition and germination), as well as in response to oxidative agents and during interaction with neutrophils. PbCATP was preferentially expressed in the pathogenic yeast phase, and was associated to the response against exogenous H2O2. Therefore, we created and analyzed the virulence defects of a knockdown strain for this isoform, and found that CATP protects yeast cells from H2O2 generated in vitro and is relevant during lung infection. On the other hand, CATA and CATB seem to contribute to ROS homeostasis in Paracoccidioides cells, during endogenous oxidative stress. CAT isoforms in Paracoccidioides might be coordinately regulated during development and dimorphism, and differentially expressed in response to different stresses to control ROS homeostasis during the infectious process, contributing to the virulence of Paracoccidioides. © 2017 Elsevier Inc.Ítem Three-dimensional evaluation of mandibular bone regenerated by bone transport distraction osteogenesis(SPRINGER, 2011-07-01) Kontogiorgos, E.; Elsalanty, M.E.; Zapata, U.; Zakhary, I.; Nagy, W.W.; Dechow, P.C.; Opperman, L.A.; Kontogiorgos, E.; Elsalanty, M.E.; Zapata, U.; Zakhary, I.; Nagy, W.W.; Dechow, P.C.; Opperman, L.A.; Universidad EAFIT. Departamento de Ingeniería de Producción; Materiales de IngenieríaThe purpose of this study was to evaluate the structure and material properties of native mandibular bone and those of early regenerate bone, produced by bone transport distraction osteogenesis. Ten adult foxhounds were divided into two groups of five animals each. In all animals, a 3- to 4-cm defect was created on one side of the mandible. A bone transport reconstruction plate, consisting of a reconstruction plate with an attached intraoral transport unit, was utilized to stabilize the mandible and regenerate bone at a rate of 1 mm/day. After the distraction period was finished, the animals were killed at 6 and 12 weeks of consolidation. Micro-computed tomography was used to assess the morphometric and structural indices of regenerate bone and matching bone from the unoperated contralateral side. Significant new bone was formed within the defect in the 6- and 12-week groups. Significant differences (P = 0.05) between mandibular regenerated and native bone were found in regard to bone volume fraction, mineral density, bone surface ratio, trabecular thickness, trabecular separation, and connectivity density, which increased from 12 to 18 weeks of consolidation. We showed that regenerated bone is still mineralizing and that native bone appears denser because of a thick outer layer of cortical bone that is not yet formed in the regenerate. However, the regenerate showed a significantly higher number of thicker trabeculae. © 2011 Springer Science+Business Media, LLC.Ítem Three-dimensional evaluation of mandibular bone regenerated by bone transport distraction osteogenesis(SPRINGER, 2011-07-01) Kontogiorgos, E.; Elsalanty, M.E.; Zapata, U.; Zakhary, I.; Nagy, W.W.; Dechow, P.C.; Opperman, L.A.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)The purpose of this study was to evaluate the structure and material properties of native mandibular bone and those of early regenerate bone, produced by bone transport distraction osteogenesis. Ten adult foxhounds were divided into two groups of five animals each. In all animals, a 3- to 4-cm defect was created on one side of the mandible. A bone transport reconstruction plate, consisting of a reconstruction plate with an attached intraoral transport unit, was utilized to stabilize the mandible and regenerate bone at a rate of 1 mm/day. After the distraction period was finished, the animals were killed at 6 and 12 weeks of consolidation. Micro-computed tomography was used to assess the morphometric and structural indices of regenerate bone and matching bone from the unoperated contralateral side. Significant new bone was formed within the defect in the 6- and 12-week groups. Significant differences (P = 0.05) between mandibular regenerated and native bone were found in regard to bone volume fraction, mineral density, bone surface ratio, trabecular thickness, trabecular separation, and connectivity density, which increased from 12 to 18 weeks of consolidation. We showed that regenerated bone is still mineralizing and that native bone appears denser because of a thick outer layer of cortical bone that is not yet formed in the regenerate. However, the regenerate showed a significantly higher number of thicker trabeculae. © 2011 Springer Science+Business Media, LLC.Ítem Zylerberg, 1985 Contributions of the layer topology and mineral content to the elastic modulus and strength of fish scales(ELSEVIER SCIENCE BV, 2018-02-01) Murcia, S.; Miyamoto, Y.; Varma, M.P.; Ossa, A.; Arola, D.Fish scales are an interesting natural structural material and their functionality requires both flexibility and toughness. Our previous studies identified that there are spatial variations in the elastic properties of fish scales corresponding to the anatomical regions, and that they appear to be attributed to changes in the microstructure. In the present study, a model is proposed that describes the elastic behavior of elasmoid fish scales in terms of the relative contributions of the limiting layer and both the internal and external elasmodine. The mechanical properties of scales from the Megalops atlanticus (i.e. tarpon) were characterized in tension and compared with predictions from the model. The average error between the predicted and the experimental properties was 7%. It was found that the gradient in mineral content and aspect ratio of the apatite crystals in the limiting layer played the most important roles on the elastic modulus of the scales. Furthermore, misalignment of plies in the external elasmodine from the longitudinal direction was shown to reduce the elastic modulus significantly. This is one approach for modulating the fish scale flexibility for a high mineral content that is required to increase the resistance to puncture. © 2017