Logotipo del repositorio
  • English
  • Español
  • Français
  • Português
  • Iniciar sesión
    ¿Has olvidado tu contraseña?
Logotipo del repositorio
  • Comunidades
  • Listar por
  • English
  • Español
  • Français
  • Português
  • Iniciar sesión
    ¿Has olvidado tu contraseña?
  1. Inicio
  2. Examinar por materia

Examinando por Materia "Titanium meshes"

Mostrando 1 - 2 de 2
Resultados por página
Opciones de ordenación
  • No hay miniatura disponible
    Ítem
    Diseño y manufactura de un implante personalizado de cráneo
    (SPRINGER, 2013-01-01) Isaza, J.F.; Correa, S.; Franco, J.M.; Torres, C.; Bedoya, B.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)
    This paper describes the methodology used to design a custom-made cranial implant for a 26 year-old patient, who suffered a lesion in the left frontoparietal region of the skull caused by a fibrous dysplasia. The design of the implant was carried out from the 3D reconstruction of the skull of the patient, obtained by a CT- Scan, using Rapid Form 2006. Once the preliminary design was obtained, 3D models of the injured region of the skull and implant were fabricated in a Rapid Prototyping (RP) machine using the Fused Deposition Modeling Technology (FDM) with the purpose of making a functional and dimensional validation of the implant. Subsequently, the implant was fabricated in titanium alloy (Ti6Al4V). With the methodology, the prosthesis was successfully implanted. The surgical time decreased by 50%, compared with the same type of surgery in which standard commercial implants and titanium meshes are used; due, principally, to the need of implementing trial and error procedures, which intend to achieve a good fit of the implant increasing the risk of the patient. Finally, the aesthetic appearance of the patient was recovered, allowing the patient to safely perform daily activities. © 2013 Springer.
  • No hay miniatura disponible
    Ítem
    Diseño y manufactura de un implante personalizado de cráneo
    (SPRINGER, 2013-01-01) Isaza, J.F.; Correa, S.; Franco, J.M.; Torres, C.; Bedoya, B.
    This paper describes the methodology used to design a custom-made cranial implant for a 26 year-old patient, who suffered a lesion in the left frontoparietal region of the skull caused by a fibrous dysplasia. The design of the implant was carried out from the 3D reconstruction of the skull of the patient, obtained by a CT- Scan, using Rapid Form 2006. Once the preliminary design was obtained, 3D models of the injured region of the skull and implant were fabricated in a Rapid Prototyping (RP) machine using the Fused Deposition Modeling Technology (FDM) with the purpose of making a functional and dimensional validation of the implant. Subsequently, the implant was fabricated in titanium alloy (Ti6Al4V). With the methodology, the prosthesis was successfully implanted. The surgical time decreased by 50%, compared with the same type of surgery in which standard commercial implants and titanium meshes are used; due, principally, to the need of implementing trial and error procedures, which intend to achieve a good fit of the implant increasing the risk of the patient. Finally, the aesthetic appearance of the patient was recovered, allowing the patient to safely perform daily activities. © 2013 Springer.

Vigilada Mineducación

Universidad con Acreditación Institucional hasta 2026 - Resolución MEN 2158 de 2018

Software DSpace copyright © 2002-2025 LYRASIS

  • Configuración de cookies
  • Enviar Sugerencias