Examinando por Autor "Velásquez, A. A."
Mostrando 1 - 11 de 11
Resultados por página
Opciones de ordenación
Ítem Caracterización de Imanes para aplicación en sistemas de sensado de posición(Sociedad Colombiana de Física, 2010-06-25) Guarin, Nicolas; Velásquez, A. A.; Mecánica AplicadaThis paper reports the characterization of a set of Neodymium magnets with different sizes and geometries, which is devoted to determine the influence of the former parameters both in the magnitude as in the direction of the magnetic fieldÍtem Caracterización de Imanes para aplicación en sistemas de sensado de posición(Sociedad Colombiana de Física, 2010-06-25) Guarin, Nicolas; Velásquez, A. A.; Universidad EAFIT. Departamento de Ciencias Básicas; Electromagnetismo Aplicado (Gema)This paper reports the characterization of a set of Neodymium magnets with different sizes and geometries, which is devoted to determine the influence of the former parameters both in the magnitude as in the direction of the magnetic fieldÍtem Diseño y construcción de un reactor mecatrónico para el crecimiento de películas delgadas por la técnica de recubrimiento por inmersión.(Fondo Editorial Universidad EAFIT, 2014-01-01) Velásquez, A. A.; Gutíerrez, Yhefferson Fernando; URQUIJO, J. P; Universidad EAFIT. Departamento de Ciencias Básicas; Electromagnetismo Aplicado (Gema)Se presenta el diseño y construcción de un sistema mecatrónico automatizado para el crecimiento de películas delgadas por la técnica de recubrimiento por inmersión. El sistema consta de un porta sustrato que realiza desplazamientos verticales...Ítem Diseño y construcción de un teslámetro digital embebido para la caracterización magnética de materiales(Universidad EAFIT, 2014-12-19) Velásquez, A. A.; Baena Rodríguez, Juliana; Gutiérrez Loaiza, Yhefferson FernandoÍtem Diseño y construcción de un teslámetro digital embebido para la caracterización magnética de materiales.(Fondo Editorial Universidad EAFIT, 2014-06-20) Velásquez, A. A.; Baena, Juliana; Gutíerrez, Yhefferson Fernando; Universidad EAFIT. Departamento de Ciencias Básicas; Electromagnetismo Aplicado (Gema)We present the design, construction and validation of an embedded digital teslameter, intended for use in experiments of magnetic materials characterization by inductive and static methods. The teslameter consists of a planar type Hall effect transducer..Ítem Laboratorios remotos: Diversos escenarios de trabajo(Universidad de Los Andes, 2011-12-01) Arroyave, M.; Velásquez, A. A.; Olarte, Tomás; Montoya, Juan Carlos; Universidad EAFIT. Departamento de Ingeniería de Sistemas; I+D+I en Tecnologías de la Información y las ComunicacionesLos laboratorios como lugares de experimentación son una herramienta de gran importancia en la educación y la investigación, ya que permiten entender mejor los conceptos y también permiten construir nuevo conocimiento. Sin embargo contar con laboratoriosÍtem Laboratorios remotos: Diversos escenarios de trabajo(Universidad de Los Andes, 2011-12-01) Arroyave, M.; Velásquez, A. A.; Olarte, Tomás; Montoya, Juan Carlos; Universidad EAFIT. Departamento de Ciencias Básicas; Electromagnetismo Aplicado (Gema)Los laboratorios como lugares de experimentación son una herramienta de gran importancia en la educación y la investigación, ya que permiten entender mejor los conceptos y también permiten construir nuevo conocimiento. Sin embargo contar con laboratoriosÍtem large magnitude late holocene seismic activity in the Pereira - Armenia region, Colombia(The Geological Society of America, 2011-01-01) Lalinde, Claudia Patricia; Toro, G.; Velásquez, A. A.; Audermad, Franck A.The Pereira-Armenia region, located west of the Colombian Central Cordillera, is crosscut by the Romeral fault system, which consists of an active north-south?trending, left-lateral, strike-slip fault system with a secondary thrust componentÍtem large magnitude late holocene seismic activity in the Pereira - Armenia region, Colombia(The Geological Society of America, 2011-01-01) Lalinde, Claudia Patricia; Toro, G.; Velásquez, A. A.; Audermad, Franck A.The Pereira-Armenia region, located west of the Colombian Central Cordillera, is crosscut by the Romeral fault system, which consists of an active north-south?trending, left-lateral, strike-slip fault system with a secondary thrust componentÍtem Simulation and parameterization by the finite element method of a C Shape Delectromagnet for application in the characterization of magnetic properties of materials(World Academy of Science Engineering and Technology, 2012-11-22) Velásquez, A. A.; Baena, Juliana; Universidad EAFIT. Departamento de Ciencias Básicas; Electromagnetismo Aplicado (Gema)This article presents the simulation, parameterization and optimization of an electromagnet with the C?shaped configuration, intended for the study of magnetic properties of materials -- The electromagnet studied consists of a C-shaped yoke, which provideÍtem Synthesis and characterization of magnetite-maghemite nanoparticles obtained by the high-energy ball milling method(Springer Netherlands, 2018-03-13) Velásquez, A. A.; Marín, C; Urquijo, P; Universidad EAFIT. Departamento de Ciencias Básicas; Electromagnetismo Aplicado (Gema)We present the process of synthesis and characterization of magnetite-maghemite nanoparticles by the ball milling method. The particles were synthesized in a planetary ball mill equipped with vials and balls of tempered steel, employing dry and wet conditions. For dry milling, we employed microstructured analytical-grade hematite (a-Fe2O3), while for wet milling, we mixed hematite and deionized water. Milling products were characterized by X-ray diffraction, transmission electron microscopy, room temperature Mössbauer spectroscopy, vibrating sample magnetometry, and atomic absorption spectroscopy. The Mössbauer spectrum of the dry milling product was well fitted with two sextets of hematite, while the spectrum of the wet milling product was well fitted with three sextets of spinel phase. X-ray measurements confirmed the phases identified by Mössbauer spectroscopy in both milling conditions and a reduction in the crystallinity of the dry milling product. TEM measurements showed that the products of dry milling for 100 h and wet milling for 24 h consist of aggregates of nanoparticles distributed in size, with mean particle size of 10 and 15 nm, respectively. Magnetization measurements of the wet milling product showed little coercivity and a saturation magnetization around 69 emu g-1, characteristic of a nano-spinel system. Atomic absorption measurements showed that the chromium contamination in the wet milling product is approximately two orders of magnitude greater than that found in the dry milling product for 24 h, indicating that the material of the milling bodies, liberated more widely in wet conditions, plays an important role in the conversion hematite-spinel phase. © 2018, Springer Science+Business Media B.V., part of Springer Nature.