Examinando por Autor "Bedoya, B."
Mostrando 1 - 6 de 6
Resultados por página
Opciones de ordenación
Ítem Diseño y manufactura de un implante personalizado de cráneo(SPRINGER, 2013-01-01) Isaza, J.F.; Correa, S.; Franco, J.M.; Torres, C.; Bedoya, B.This paper describes the methodology used to design a custom-made cranial implant for a 26 year-old patient, who suffered a lesion in the left frontoparietal region of the skull caused by a fibrous dysplasia. The design of the implant was carried out from the 3D reconstruction of the skull of the patient, obtained by a CT- Scan, using Rapid Form 2006. Once the preliminary design was obtained, 3D models of the injured region of the skull and implant were fabricated in a Rapid Prototyping (RP) machine using the Fused Deposition Modeling Technology (FDM) with the purpose of making a functional and dimensional validation of the implant. Subsequently, the implant was fabricated in titanium alloy (Ti6Al4V). With the methodology, the prosthesis was successfully implanted. The surgical time decreased by 50%, compared with the same type of surgery in which standard commercial implants and titanium meshes are used; due, principally, to the need of implementing trial and error procedures, which intend to achieve a good fit of the implant increasing the risk of the patient. Finally, the aesthetic appearance of the patient was recovered, allowing the patient to safely perform daily activities. © 2013 Springer.Ítem Diseño y manufactura de un implante personalizado de cráneo(SPRINGER, 2013-01-01) Isaza, J.F.; Correa, S.; Franco, J.M.; Torres, C.; Bedoya, B.; Universidad EAFIT. Departamento de Ingeniería Mecánica; Bioingeniería GIB (CES – EAFIT)This paper describes the methodology used to design a custom-made cranial implant for a 26 year-old patient, who suffered a lesion in the left frontoparietal region of the skull caused by a fibrous dysplasia. The design of the implant was carried out from the 3D reconstruction of the skull of the patient, obtained by a CT- Scan, using Rapid Form 2006. Once the preliminary design was obtained, 3D models of the injured region of the skull and implant were fabricated in a Rapid Prototyping (RP) machine using the Fused Deposition Modeling Technology (FDM) with the purpose of making a functional and dimensional validation of the implant. Subsequently, the implant was fabricated in titanium alloy (Ti6Al4V). With the methodology, the prosthesis was successfully implanted. The surgical time decreased by 50%, compared with the same type of surgery in which standard commercial implants and titanium meshes are used; due, principally, to the need of implementing trial and error procedures, which intend to achieve a good fit of the implant increasing the risk of the patient. Finally, the aesthetic appearance of the patient was recovered, allowing the patient to safely perform daily activities. © 2013 Springer.Ítem Haciendo florecer el ecosistema: Análisis del apoyo a las industrias culturales y creativas en Colombia y el mundo(2020-05-01) Podesta, M.; Hernandez, M.; Bedoya, B.Ítem Haciendo florecer el ecosistema: Análisis del apoyo a las industrias culturales y creativas en Colombia y el mundo(2020-10-07) Podesta, M.; Hernandez, M.; Bedoya, B.; Universidad EAFIT. Departamento de Ingeniería de Diseño; Ingeniería de Diseño (GRID)Ítem Metodología ACTIVAR: aplicación concreta de una técnica innovadora para dar valor al aprendizaje requerido, una herramienta para enriquecer la docencia(Fondo Editorial Universidad EAFIT, 2008-10-01) Podesta, M.; Martinez, J.; López Vega, Ricardo Andrés; Bedoya, B.; Álvarez, Juan EstebanÍtem Metodología ACTIVAR: aplicación concreta de una técnica innovadora para dar valor al aprendizaje requerido, una herramienta para enriquecer la docencia(Fondo Editorial Universidad EAFIT, 2008-10-01) Podesta, M.; Martinez, J.; López Vega, Ricardo Andrés; Bedoya, B.; Álvarez, Juan Esteban; Universidad EAFIT. Departamento de Ingeniería de Diseño; Ingeniería de Diseño (GRID)